PDUMNH32HVAT Datasheet, PDF (1/4 Pages) Tripp Lite. All Rights Reserved – 7.4kW Single-Phase 230V ATS/Monitored PDU, IEC309 32A Blue Outlet, 2 IEC309 32A Blue Inputs, 1U Rack-Mount
7.4kW Single-Phase 230V ATS/Monitored PDU,
IEC309 32A Blue Outlet, 2 IEC309 32A Blue Inputs,
1U Rack-Mount
MODEL NUMBER: PDUMNH32HVAT
Highlights
Two IEC 309 32A Blue (2P+E)
inputs w/10 ft. (3 m) cords
IEC 309 32A Blue (2P+E) outlet
for connecting device or 0U PDU
Automatic transfer switching
within 1–5 ms
Ethernet network interface for
remote access
Digital display with LEDs for
real-time status monitoring
Package Includes
PDUMNH32HVAT 7.4kW
Single-Phase 230V
ATS/Monitored PDU
Rack-mounting brackets
PDU4PKIT rear support rail kit
Owner’s manual
Description
The PDUMNH32HVAT 7.4kW Single-Phase 230V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices
with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an
IEC 309 32A Blue outlet for connecting a single device or an additional 230V PDU with IEC 309 32A Blue plug, such as Tripp Lite’s PDUMV32HV.
Dual 10-foot(3-meter) input cords with IEC 309 32A Blue plugs connect to separate primary and secondary single-phase power sources, including
out-of-phase sources. The PDU constantly evaluates the power quality of both input sources. To ensure connected equipment remains powered, dynamic
solid-state(TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes
unstable.
Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet
or SNMP. Provides real-time load/current data with billing-grade accuracy(+/- 1 percent). Tiered access privileges allow both an administrator and a guest to
log in. Automated alerts help prevent overloads, power loss and downtime. Digital display with LEDs indicates power availability, voltage, input status for both
power sources, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module(sold separately).
Features
Primary and Secondary Inputs for Power Redundancy
Offers remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
IEC 309 32A Blue(2P+E) inputs with 10 ft.(3 m) cords connect to separate primary and secondary single-phase power sources
Fault-tolerant, hot-swappable UPS protection when used with single UPS
Fully redundant UPS protection when each cord is connected to separate UPS
Built-In IEC 309 32A Blue Outlet
Powers a single device or indirectly powers equipment through a 0U 230V PDU with IEC 309 32A Blue(2P+E) input(sold separately)
1/4