PDUMNH16HVAT Datasheet, PDF (1/4 Pages) Tripp Lite. All Rights Reserved – 3.7kW Single-Phase 230V ATS/Monitored PDU, IEC309 16A Blue Outlet, 2 IEC309 16A Blue Inputs, 1U Rack-Mount
3.7kW Single-Phase 230V ATS/Monitored PDU,
IEC309 16A Blue Outlet, 2 IEC309 16A Blue Inputs,
1U Rack-Mount
MODEL NUMBER: PDUMNH16HVAT
Highlights
Two IEC309 16A Blue (2P+E)
inputs with 10 ft. cords
IEC309 16A Blue outlet (2P+E)
for connecting device or 0U PDU
Automatic transfer switching
within 1–5 ms
Ethernet network interface for
remote access
Digital display with LEDs for
real-time status monitoring
Package Includes
PDUMNH16HVAT 3.7kW
Single-Phase 230V
ATS/Monitored PDU
Rack-mounting brackets
Owner’s manual
Description
The PDUMNH16HVAT 3.7kW Single-Phase 230V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices
with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an
IEC309 16A Blue outlet for connecting a single device or a 0U 230V vertical PDU with IEC309 16A Blue plug.
Dual 10-foot input cords with IEC309 16A Blue plugs connect to separate primary and secondary single-phase power sources, including out-of-phase sources.
The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state(TRIAC) automatic transfer switching allows the PDU to switch to the
secondary source within 1–5 milliseconds if the primary source fails or becomes unstable to ensure connected equipment remains powered.
Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet
or SNMP. Provides real-time load/current data with billing-grade accuracy(+/- 1 percent). Tiered access privileges allow both an administrator and a guest to
log in. Automated alerts help prevent overloads, power loss and downtime. Digital display with LEDs indicates power availability, voltage, input status for both
power sources, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module(sold separately).
Features
Primary and Secondary Inputs for Power Redundancy
Offers remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
IEC309 16A Blue(2P+E) inputs with 10 ft. cords connect to separate primary and secondary single-phase power sources
Fault-tolerant, hot-swappable UPS protection when used with single UPS; fully redundant UPS protection when each cord is connected to a separate UPS
Built-In IEC309 16A Blue Outlet
Powers a single device or indirectly powers equipment through a 0U 230V PDU with IEC309 16A Blue input(sold separately)
Automatic Transfer Switching
Dynamic solid-state(TRIAC) automatic transfer switching
1/4