English
Language : 

VPS10-17500 Datasheet, PDF (1/1 Pages) TRIAD MAGNETICS – POWER TRANSFORMER CHASSIS MOUNT : CONNECT WORLD SERIES
POWER TRANSFORMER
CHASSIS MOUNT : CONNECT WORLD SERIES
VPS10-17500
Electrical Specifications (@25C)
1. Maximum Power: 175.0VA
2. Secondary: Series: 10.0V CT@ 17.5A
Parallel: 5.0V @ 35.0A
3. Voltage Regulation: 25% TYP @ full load to no load
4. Temperature Rise: 30C TYP ( 45C MAX allowed)
5. Insulation Resistance: 100M
Construction:
Dual bobbin construction with an insulated shroud, both made of a high temperature
material that exceeds UL flammability requirements.
Safety:
These units are designed with 4000VAC isolation between the primary and secondary,
and also, between each winding and the core. Since the dual bobbin construction
D
effectively reduces capacitance, electrostatic shielding is not required. World Series
B
Transformers are designed and manufactured to meet the following agency
approvals:
Agency File:
UL: File E53148, UL 506, General Purpose.
CSA: File LR 37220. C22.2 NO. 66, General Purpose.
VDE: File 18786-3390-0001, VDE/EN 60 950, (IEC950) information
Technology Equipment.
A. Dimensions:
H
W
D
A
B
C
3-3/4 3-1/8 2-13/16 - 1-5/8 3/8
Unit: In inches
T
MW
ML
1/4 2-1/2 2-1/2
B. Mounting Hole Size: 13/64”X3/8”
C. WT Lbs. : 5.5
D. Schematic Diagram:
6
12
PARALLEL
CONNECTION
115/230V 5
50/60Hz 2
1
6
11
115V
5
8
50/60Hz
2
1
7
SERIES
CONNECTION
6
230V
5
50/60Hz
2
1
* Upon printing,this document is considered”uncontrolled”.Please contact
Triad Magnetics’ website for the most current version.
C
W
6
12
5
11
H
2
8
1
7
T
ML
MW
Web: www.TriadMagnetics.com
Phone 909-277-0757
Fax 909-277-2757
22520B Temescal Canyon Road
Corona, California
92883
Release Date: March 18, 2004
Revision: Initial Release