English
Language : 

TY-403P_13 Datasheet, PDF (1/1 Pages) TRIAD MAGNETICS – Audio Transformer Data coupling
Audio Transformer
Data/Voice Coupling
T Y- 4 0 3 P
Description:
The TY series transformers are used for a variety of applications including
impedance matching, isolation, repeat coil, line balancing, bridging and
hybrid circuit.
Electrical Specifications at 25º C:
Impedance Max. DC Typ.
Typ. Typ. Freq.
(Ohms) Current Insertion Return Response
Pri Sec (mA) Loss (dB) Loss (dB) (dB)
600 600§ 90
1.75
15
±.5
§ = Split Secondary
Designed to meet FCC Part 68
Longitudinal Balance: (FCC 68.310) – 60 dB min. 200 – 1000 Hz
45 dB min. 1000 – 4000 Hz
Dielectric Strength: (FCC 68.304) – 1500VAC
Power Level: -45 dBm to +7 dBm
Frequency Range: 300 to 3500 Hz
PIN #1 AT KEY
.53 TYP
.950 ± .020
1.25 TYP
.815 TYP
Electrical Schematic:
1
2
PRIMARY
600
OHM
SECONDARY
5
3
600
OHM
6
4
RoHS Compliance: As of manufacturing date February 2005, all standard
products meet the requirements of 2011/65/EU, known as the RoHS initiative.
*Upon printing, this document is considered “uncontrolled”.Please contact
Triad Magnetics website for the most current version.
.20 ± .010
12 3
.20 TYP
654
web:www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013