Electrical Specifications at 25º C:
Impedance Max. DC Typ.
Typ. Typ. Freq.
(Ohms)
Current Insertion Return Response
Pri Sec (mA) Loss (dB) Loss (dB) (dB)
600CT 600CT 90
1.75
15
±.5
CT = Center Tap
Designed to meet FCC Part 68
Longitudinal Balance: (FCC 68.310) – 60 dB min. 200 – 1000 Hz
45 dB min. 1000 – 4000 Hz
Dielectric Strength: (FCC 68.304) – 1500VAC
Power Level: -45 dBm to +7 dBm
Frequency Range: 300 to 3500 Hz
Outline Dimensions:
A
B
C
.820 Max .750 Max .715 Max
DOT ABOVE #1 PIN
ON BOBBIN FLANGE
A
B
.187 REF
1 23
C
Electrical Schematic:
1
600 Ohms
2
4
5
600 Ohms
.187 .187
6
5
4
.060 DIA HOLES
.420
3
6
RoHS Compliance: As of manufacturing date February 2005, all standard
products meet the requirements of 2011/65/EU, known as the RoHS initiative.
1
2
3
*Upon printing, this document is considered “uncontrolled”.Please contact
Triad Magnetics website for the most current version.
web:www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013