English
Language : 

TY-306P_13 Datasheet, PDF (1/1 Pages) TRIAD MAGNETICS – Audio Transformer Data coupling
Audio Transformer
Data/Voice Coupling
T Y- 3 0 6 P
Description:
The TY series transformers are used for a variety of applications including
impedance matching, isolation, repeat coil, line balancing, bridging and hybrid
circuits.
Electrical Specifications at 25º C:
Impedance
(Ohms)
Pri Sec
600§ 600
§ = Split Winding
Max. DC Typ.
Typ. Typ. Freq.
Current Insertion Return Response
(mA) Loss (dB) Loss (dB) (dB)
75
1.5
10
±.5
Designed to meet FCC Part 68
Longitudinal Balance: (FCC 68.310) – 60 dB min. 200 – 1000 Hz
45 dB min. 1000 – 4000 Hz
Dielectric Strength: (FCC 68.304) – 1500VAC
Power Level: -45 dBm to +7 dBm
Frequency Range: Data/Voice = 300 to 3500 Hz
Data = 800 to 3500 Hz
Schematic:
6
PRIMARY
600
5
8
3
SECONDARY
600
OHM
8
1
1.65 TYP
4
5
1.375 TYP
1
.200
.750
8
.250 (3 PLCS)
.062 DIA (8 PLCS)
OHM
2
7
RoHS Compliance: As of manufacturing date February 2005, all standard
products meet the requirements of 2011/65/EU, known as the RoHS initiative.
4
5
1.00
UNIT MOUNTING PATTERN
*Upon printing, this document is considered “uncontrolled”.Please contact Triad
Magnetics website for the most current version.
web:www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013