English
Language : 

TY-300P_13 Datasheet, PDF (1/1 Pages) TRIAD MAGNETICS – Audio Transformer Data coupling
Audio Transformer
Data/Voice Coupling
T Y- 3 0 0 P
Description:
The TY series transformers are used for a variety of applications including
impedance matching, isolation, repeat coil, line balancing, bridging and
hybrid circuit.
Electrical Specifications at 25º C:
Impedance
Max. DC Typ.
Typ. Trans-Hybrid
(Ohms)
Current Insertion Return
Loss
Pri
Sec
(mA) Loss (dB) Loss (dB)
(dB)
600 (4W) 600/600
0
.80
30
50
Designed to meet FCC Part 68
Longitudinal Balance: (FCC 68.310) – 60 dB min. 200 – 1000 Hz
45 dB min. 1000 – 4000 Hz
Dielectric Strength: (FCC 68.304) – 1500VAC
Power Level: -45 dBm to +7 dBm
Frequency Range: 300 to 3500 Hz
Electrical Schematic:
1
PRI
Z = 600
6
3
SEC 1
Z = 600
4
2
SEC 2
Z = 600
5
DOT ABOVE #1 PIN
ON BOBBIN FLANGE
.812 MAX
.740
MAX
.150 MIN
123
PINS
.040 X .016
MAX
.715
.187 .187
6
5
4
.060 DIA HOLES
.420 + .025, -.015
RoHS Compliance: As of manufacturing date February 2005, all standard
products meet the requirements of 2011/65/EU, known as the RoHS initiative.
1
2
3
*Upon printing, this document is considered “uncontrolled”.Please contact
Triad Magnetics website for the most current version.
web:www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013