English
Language : 

TLD1020-24 Datasheet, PDF (1/1 Pages) TRIAD MAGNETICS – Switch Mode Power Supplies Encapsulated Constant Voltage
Switch Mode Power Supplies
Encapsulated Constant Voltage
TLD1020-24
Description:
The TLD1020-24 is a compact and lightweight Constant Voltage Switch Mode Power Supply.
Waterproof design within a 2x4 J box, IP66, NEMA 4 suitable for dry and damp locations.
Convection cooled plastic housing. Designed for outdoor and indoor applications. Some typical
applications include LED’s, Lighting, etc.
Specifications (@25C)
Electrical Specifications:
Input Voltage:
Input Frequency Range:
Max Input Current:
Max Inrush Current:
Power Factor:
Output:
Crest Factor (Ipk):
Leakage Current:
Efficiency:
Maximum power:
Current Accuracy:
Load Regulation:
Hold up time:
Protection:
100-304Vac1
47-63Hz
0.3A @ 115Vac; 0.15A @ 230Vac
<5A@115Vac, 10A@220Vac
>0.9 at full load, 115Vac
24Vdc±5%, .830Adc Max
1.5 Max.
300µA Typical
84% Typical at full load
20W
±1% (when applicable)
±3%
Half cycle minimum at 120 VAC and 80% of rated voltage
Over-voltage, Over current and Short circuit protection:
Auto-recovery
Environmental Specifications:
Operating Temperature:
-30 to 60°C (De-rating: 1%/°C from 60-70°C)
Storage Temperature:
-40 to 85°C
Operating Humidity:
5 to 95% RH (non-Condensing)
Cooling:
Convection cooling
Vibration:
5 to 50Hz
MTBF:
>100,000 Hours at full load and 25°C ambient conditions
EMC:
Compliant to 47CFR, Part 2, Part 15 and Cispr PUB, 22
Class B
General Specifications:
Connections:
Dimensions (WxLxH):
Weight:
Warranty:
5in leads - Input: 18 AWG; Output: 18 AWG, Black (-), Gray (+)
40.0x95.0x25mm
120g
3 years @ 40°C, 100% Load
Safety Standards:
Standards:
UL (cUL) 1310, UL48
CE
For Illustration Only
5 (0.20)
(2X)
3.6 (0.14)
(2X)
40 (1.57)
4 (0.16)
(2X)
10 (0.39)
(2X)
RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements
of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for the
most current version.
1 Parts manufactured before November, 2010 have an input voltage range of 90 – 264VAC.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013