English
Language : 

N-2X Datasheet, PDF (1/1 Pages) TRIAD MAGNETICS – CHASSIS MOUNT : Autotransformer
POWER TRANSFORMER
CHASSIS MOUNT : Autotransformer
N-2X
Electrical Specifications (@25ºC)
1. Maximum Power: 100 VA
2. Input Voltage:
230 V, 50 / 60 Hz
3. Output Voltage
115V, + 5%
4. Full Secondary Load 0.87 Amps RMS
5. Temperature Rise: 60C TYP ( 85C MAX allowed)
from 25º C, Ambient
Construction:
Single winding on a double wall, nylon bobbin. This chassis mount design
comes in a channel frame with .187” diameter holes in the mounting ears.
Three leads exit the transformer, the black lead is the tap.
Description:
Secondary coil is a fraction of the entire winding for voltage step-down.
This causes part of the power to be transferred conductively through the
windings, rather than all of the power being transferred by induction.
.187 DIA.
2 HOLES
Safety:
These units are designed with 1500V isolation between the winding and the
core. Materials and construction are rated for Class B insulation system.
4.0
REF
3.562
+/-.030
E50476
A. Dimensions:
H
W
2.562
4.0
D
A
B
C
1.93 2-5/16 1-1/8 5/16
Unit: In inches
T
MW
ML
3/16 3.562
-
REF
1.93
B. Lead Connections:
Primary (230V) Wht
to Red
Red
Black
Secondary (115V) Wht
to Black
C. Weight : 2.1 lbs
White
RoHS Compliance: As of manufacturing date February 2005, all standard products
meet the requirements of 2011/65/EU, known as the RoHS initiative.
N-2X
REF
2.562
W HT BLK RE D
* Upon printing,this document is considered”uncontrolled”.Please contact
Triad Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: May 11, 2015