English
Language : 

F120-300 Datasheet, PDF (1/1 Pages) TRIAD MAGNETICS – PC MOUNT : SPLIT PACK
POWER TRANSFORMER
P C M O U N T : SPLIT PACK
F120-300
Description:
The F120-300 is a single primary and dual secondary, split bobbin design which
operates with an input of 115V. The output voltage will be either 120.0V with a
center-tap under a 0.3A load with the secondaries wired in series, or 60.0V
under a 0.6A load with the secondaries wired in parallel. The split bobbin design
eliminates the need for costly electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 36.0VA
2. Primary: 115V
3. Secondary: Series: 120.0V CT@ 0.3A
Parallel: 60.0V @ 0.6A
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 2500 VRMS
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling.
Agency File:
UL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
cUL: File E53148, UL 5085-2 (506), Class B General Purpose Transformer,
Canadian Use (CSA 22.2, No.66.2-06)
W
E
L
Dimensions:
H
W
1.562 2.187
Weight: 1.10 lbs
L
2.625
A
0.400
B
0.400
C
1.850
Units in inches.
D
E
F
0.041 0.020 0.234
Schematic:
5
1
115V
6
50/60Hz 4
7
8
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
As of April 7, 2008, UL standards 506 and 1585 will be migrated to UL 5085-2
and 5085-3, respectively.
* Upon printing, this document is considered ”uncontrolled”. Please contact
Triad Magnetics’ website for the most current version.
H
1
4
D
F
A
5
A
8
B
C
1
4
0.06" DIAMETER
HOLE
Board Layout
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013