English
Language : 

F12-090-C2 Datasheet, PDF (1/1 Pages) TRIAD MAGNETICS – CLASS 2 TRANSFORMER
CLASS 2 TRANSFORMER
F12-090-C2
Description:
The F12-090-C2 is a single primary and dual secondary, split bobbin design which
operates with an input of 115V. The secondaries are 6.3V @ 0.09A each. They can
be used independently (up to 300V difference between them) or in series for double
the voltage or in parallel for double the current. The split bobbin design eliminates
the need for costly electrostatic shielding.
Electrical Specifications (@25C)
1. Maximum Power: 1.1VA
2. Primary: 115V, 50/60 Hz
3. Secondaries: 6.3V @ 0.09A each
4. Voltage Regulation: 25% TYP @ full load to no load
5. Temperature Rise: 25C TYP
6. Hipot tested 100% at 4200 VRMS pri to sec
7. Hipot tested 100% at 2160 VRMS sec to sec
8. Inherently Limited. No fusing required.
Construction:
Three flange bobbin construction with primaries and secondaries wound side by
side for low capacitive coupling. UL Class F Insulation System (155°C).
Agency File:
UL: File E65390, UL 5085-1 & 3 (1585), Class 2 Transformer
cUL: File E65390, UL 5085-1 & 3 (1585) For Canadian Use (CSA 22.2, No.66.3-06)
Dimensions:
H
W
0.937 1.125
Weight: 0.17 lbs
L
1.375
A
0.250
B
0.250
C
1.200
Units in inches.
D
E
F
0.041 0.020 0.234
Schematic:
1
115V
50/60 Hz
4
5
6.3V @ 0.09A
6
7
6.3V @ 0.09A
8
W
E
L
H
1
4
D
F
A
5
A
8
B
C
1
4
0.06" DIAMETER
HOLE
Board Layout
RoHS Compliance: As of manufacturing date February 2005, all standard products
meet the requirements of 2011/65/EU, known as the RoHS initiative.
Note: Order and shipping documentation may have a “-B” suffix; this indicates Bulk
packaging but does not show on the actual part number marked on the transformer.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’
website for the most current version.
www.TriadMagnetics.com
Phone: (951) 277-0757
Fax: (951) 277-2757
460 Harley Knox Blvd.
Perris, CA 92571
Publish Date: December 4, 2013