English
Language : 

F-360U Datasheet, PDF (1/1 Pages) TRIAD MAGNETICS – Chassis Mount: Universal
POWER TRANSFORMER
Chassis Mount: Universal
F-360U
Electrical Specifications (@25C)
1. Maximum Power: 78 VA
2. Primary: 115/230V @ 50/60 Hz
3. Secondaries: 0-6.5/13/19.5/26V @ 3 Amps
Description:
The F-360U is a chassis mount power transformer that was designed with multiple
secondaries to give the user maximum flexibility.
Safety:
These products are 100% hi-pot tested with an insulation of 1500V between
primary and secondary windings as well as between the primary / secondary
windings and the core.
Dimensions:
H
W
D
3.375 2.812 2.625
Units: In inches
MW
MD
2.25 2.125
BLK/GRN
RED/BLK
YEL/BLK
BLK
F-360U
Weight: 3.5 lbs
All Leads 7.0” ± 1.0”
Skin & Tin: ¼” ± 1/16”
2.25
+/-.030
For Input (115V): BLK and RED/BLK to YEL/BLK and BLK/GRN
For Input (230V): BLK to BLK GRN, Tie YEL/BLK to RED/BLK
YEL
BLK
115 V
50/60 HZ
6.5 V
BLK/WHT 13 V
2.125
+/-.060
YEL/BLK
RED/BLK
115 V
50/60 HZ
BLK/GRN
RED/YEL
BRN
RED
19.5 V
26 V @ 3.0 A
BRN
SECONDARY
BLK/WHT
RED
RED/YEL
YEL
3.375
REF
Technical note: Primary windings are designed to be connected in series or parallel.
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
2.812
REF
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website
for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013