English
Language : 

F-313X_13 Datasheet, PDF (1/1 Pages) TRIAD MAGNETICS – Chassis Mount: Single Secondary
POWER TRANSFORMER
Chassis Mount: Single Secondary
F-313X
Electrical Specifications (@25C)
1. Maximum Power: 3.8 VA
2. Primary:
Series: 230V 50/60 Hz
Parallel: 115V 50/60 Hz
3. Secondary: 6.3V @ 0.600 Amps
4. Voltage Regulation: 35 % TYP @ full load to no load
5. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-313X is part of a series which has a long history of reliable service in the
field, made from a proven design and constructed with UL recognized materials.
Construction:
A
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
Safety:
These products are 100% hipot tested with an insulation of 2500V between
primary and secondary windings as well as between the primary / secondary
windings and the core.
Dimensions: Units: In inches
A
B
C
D
1.375 2.375 1.375 2.00
Mounting Hole Diameter: .187 in
Lead length: 7.0 inches + 1 inch
Weight: 0.37 lbs
BLK/GRN
RED/BLK
YEL/BLK
BLK
C
Schematic:
BLK
YEL/BLK
GRN
GRN/YEL
BD
RED/BLK
BLK/GRN
GRN
Primary:
Series: BLK to BLK/GRN, Jumper YEL/BLK to RED/BLK
Parallel: BLK to YEL/BLK, Jumper BLK to RED/BLK and YEL/BLK to BLK/GRN
GRN
Secondary: Green to Green
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
GRN
the requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013