POWER TRANSFORMER
Chassis Mount: Multiple Secondary
F-195X
Electrical Specifications (@25C)
1. Maximum Power: 19.63 VA
2. Primary: 115V 50/60 Hz
3. Secondary 1: 32.0VCT @ 0.250 Amps*
Secondary 2: 15.5VCT @ 0.750 Amps*
4. Voltage Regulation: 5 % TYP @ full load to no load
5. Temperature Rise: 35C TYP (45C MAX allowed)
Description:
The F-195X is part of a series which has a long history of reliable service in the
field, made from a proven design and constructed with UL recognized materials.
A
Construction:
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
Safety:
These products are 100% hipot tested with an insulation of 1500V between
primary and secondary windings as well as between the primary / secondary
windings and the core.
Dimensions: Units: In inches
A
B
C
D
2.250 3.750 1.875
Weight: 1.30 lbs
3.125
BL K
BL K
R ED
R ED /YEL
R ED
C
Schematic:
BLK
PRIMARY
BLK
RED
RED/YEL SEC 1
RED
GRN
GRN/YEL SEC 2
GRN
BD
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.