English
Language : 

F-166XP Datasheet, PDF (1/1 Pages) TRIAD MAGNETICS – PC Mount: Single Primary
POWER TRANSFORMER
PC Mount: Single Primary
F-166XP
Electrical Specifications (@25C)
1. Maximum Power: 7.5 VA
2. Primary: 115V 50/60 Hz
3. Secondary No 1: 24.0V CT @ 0.125 Amps
Secondary No 2: 9.0V CT @ 0.500 Amps
Description:
The F-166XP is part of a wide selection of plug-in types that meet the needs of PC
boards and solid state power supply design. This transformer can satisfy power as
well as control and instrumentation applications.
Construction:
Wound on a single channel nylon bobbin. Materials are UL recognized, Class B
(130º C) rated.
Safety:
These products are 100% hipot tested with an insulation of 1500V between
primary and secondary windings.
Dimensions:
Units: In inches
A
B
C
D
E
F
G
1.625 2.812 1.468 1.953 .250 1.312 2.375
Mounting holes: 0.187 in.
C
Pin length: 0.187 in.
Pin size: 0.20 x .041 in.
Weight: 10.5 oz
Schematic:
3
4
1
5
2
6
7
8
Primary:
Secondary No.1:
Secondary No.2:
1 to 2
3 to 5
6 to 8
D
A
13 45
G
B
E EE
2 67 8
F
13 4 5
RoHS Compliance: As of manufacturing date February 2005, all standard products meet
the requirements of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad
Magnetics’ website for the most current version.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: May 1, 2014