English
Language : 

TBL015-105 Datasheet, PDF (2/3 Pages) TRACO Electronic AG – Industrial Power Supplies
Industrial Power Supplies
TBL Series
15 to 150 Watt
Input Specifications
Input voltage
– nominal 100 – 240 VAC
– AC range 85 – 264 VAC (output power derating 5 %/V
for opertion below 90 VAC)
Input frequency 47 – 63 Hz
Harmonic limits EN 61000-3-2, Class A
Output Specifications
Output voltage adjustable range
5 VDC model: 5.0 – 5.2 VDC
12 VDC models: 12 – 16 VDC
24 VDC models: 24 – 28 VDC
Output regulation
1 %
Ripple and noise (20MHz bandwidth) < 100 mV pk-pk
Electronic short circuit protection current limitation at 100 – 150 % typ.
(automatic recovery)
Hold-up time 115 VAC
min. 10 ms
230 VAC
min. 20 ms
General Specifications
Temperature ranges
– Operating – 25 °C to +70 °C max.
Power derating
2.5 %/K above 60 °C
Humidity (non condensing) 5 – 95 % rel. H
Temperature coefficient 0.02 %/K
Safety standards UL 508, UL 1310, class II
IEC/EN 60950-1, UL 60950-1, EN 50178,
EN 60204, EN 61558-2-8
CSA C22.2 No. 60950-1 2003
Safety approvals
– CB report IEC/EN 60950-1
(TBL 150 models pending) www.tracopower.com/products/tbl_cb60950-1.pdf
– UL approval UL 508 listed
www.tracopower.com/products/tbl_ul508.pdf
UL 1310 listed
www.tracopower.com/products/tbl_ul1310.pdf
– CSA certification UL 60950-1, CSA 60950-1-03
www.tracopower.com/products/tbl_csa60950-1.pdf
– GS certification www.tracopower.com/products/tbl_gs.pdf
Electromagnetic compatibility (EMC), emissions EN 61000-6-3
– Conducted RI suppression on input EN 55022 class B
– Radiated RI suppression EN 55022 class B
Electromagnetic compatibility (EMC), immunity EN 61000-6-2
– Electrostatic discharge (ESD) EN 61000-4-2
– Radiated RF field immunity EN 61000-4-3
– Electrical fast transient / burst immunity EN 61000-4-4
– Surge immunity line – ground EN 61000-4-5
– Surge immunity line – line EN 61000-4-5
– Surge immunity output EN 61000-4-5
– Immunity to conducted RF disturbances EN 61000-4-6
– Mains voltage dips and interruptions EN 61000-4-11
4 kV / 8 kV
3 V/m
1 kV / 0.5 kV
2 kV
1 kV
0.5 kV
3V
30 % /10 mS, 60 % /100 mS
http://www.tracopower.com
Page 2 of 3