English
Language : 

MBU100 Datasheet, PDF (3/4 Pages) Total Power International – MBU100 SERIES 1WATT ULTRA MINIATURE HIGH SIP DC/DC CONVERTERS
Output Specifications
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Ripple & Noise (20MHz)
Over Load
Temperature Coefficient
Output Short Circuit
General Specification
Parameter
Rated Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
TOTAL POWER INT.
MBU100
Conditions
For Vin Change 1%
Io=20% to 100%
Over Line,Load & Temp.
Min.
Typ.
Max.
---
{1.0
{3.0
---
{1.2
{1.5
See Model Selection Guide
---
100
150
---
---
200
---
---
5
120
---
---
---
{0.01
{0.02
0.5 Second Max.
Unit
%
%
%
mV P-P
mV P-P
mV rms.
%
%/]
Conditions
60 Seconds
500VDC
100KHz,1V
Min.
1000
1000
---
50
Typ.
---
---
60
90
Max.
---
---
100
110
Unit
VDC
M[
pF
kHz
Input Fuse Selection Guide
5V Input Models
500mA Slow - Blow Type
Typical Applications
12V Input Models
200mA Slow - Blow Type
24V Input Models
100mA Slow - Blow Type
+
DC Power
Source
-
Fuse
+Vin
Single Output
DC / DC
Converter
-Vin
+Out
-Out
Load
Connecting Pin Patterns
(2.54 mm / 0.1 inch grids )
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-3-