Model Selection Guide
Model
Number
Input
Voltage
Output
Voltage
MDW1011
MDW1012
MDW1013
MDW1014
MDW1015
MDW1016
MDW1017
MDW1021
MDW1022
MDW1023
MDW1024
MDW1025
MDW1026
MDW1027
MDW1031
MDW1032
MDW1033
MDW1034
MDW1035
MDW1036
MDW1037
MDW1041
MDW1042
MDW1043
MDW1044
MDW1045
MDW1046
MDW1047
VDC
5
( 4.5 ~ 9 )
12
( 9 ~ 18 )
24
( 18 ~ 36 )
48
( 36 ~ 72 )
VDC
3.3
5
12
15
{5
{12
{15
3.3
5
12
15
{5
{12
{15
3.3
5
12
15
{5
{12
{15
3.3
5
12
15
{5
{12
{15
Output Current
Max.
Min.
mA
mA
500
125
400
100
167
42
134
33
{200
{50
{83
{21
{67
{17
500
125
400
100
167
42
134
33
{200
{50
{83
{21
{67
{17
500
125
400
100
167
42
134
33
{200
{50
{83
{21
{67
{17
500
125
400
100
167
42
134
33
{200
{50
{83
{21
{67
{17
Input Current
@Max. Load
mA (Typ.)
471
548
534
582
667
615
598
184
217
209
220
242
224
226
96
109
109
108
119
112
110
49
57
53
55
62
57
57
@No Load
mA (Typ.)
40
20
10
8
Reflected
Ripple
Current
mA (Typ.)
100
25
15
10
Efficiency
@Max. Load
% (Typ.)
70
73
75
73
64
69
71
73
77
80
80
73
78
78
72
77
80
81
74
78
80
71
73
79
79
71
77
77
Absolute Maximum Ratings
Parameter
5VDC Input Models
Input Surge Voltage
( 1000 mS )
12VDC Input Models
24VDC Input Models
48VDC Input Models
Lead Temperature (1.5mm from case for 10 Sec.)
Internal Power Dissipation
Min.
-0.7
-0.7
-0.7
-0.7
---
---
Max.
11
25
50
100
260
1,800
Unit
VDC
VDC
VDC
VDC
]
mW
Exceeding these values can damage the module. These are not continuous
operating ratings.
Environmental Specifications
Parameter
Operating Temperature
Operating Temperature
Storage Temperature
Humidity
Cooling
Conditions
Min. Max. Unit
Ambient
-40 +65
]
Case
-40 +90
]
-40 +125 ]
--- 95
%
Free-Air Convection
Note :
1. Specifications typical at Ta=+25], resistive load,
nominal input voltage, rated output current unless
otherwise noted.
2. Transient recovery time is measured to within 1%
error band for a step change in output load of 50%
to 100%.
3. Ripple & Noise measurement bandwidth is 0-20
MHz.
4. These power converters require a minimum
output loading to maintain specified regulation.
5. Operation under no-load conditions will not
damage these devices; however they may not
meet all listed specifications.
6. All DC/DC converters should be externally fused
on the front end for protection.
7. Other input and output voltage may be available,
please contact factory.
8. Specifications subject to change without notice.