DC/DC CONVERTER 1W, SIP-Package
Output Specifications
Parameter
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20MHz)
Temperature Coefficient
Short Circuit Protection
Conditions
Dual Output, Balanced Loads
For Vin Change of 1%
Io=20% to 100%
Min.
Typ.
Max.
---
±0.1
±1.0
---
±1.05
±1.2
See Model Selection Guide
---
30
60
---
±0.01
±0.02
0.5 Second Max.
Unit
%
%
mV P-P
%/℃
General Specifications
Parameter
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
Safety Approvals
Conditions
Min.
Typ.
Max.
60 Seconds
1000
---
---
500 VDC
1000
---
---
100KHz, 1V
40
60
120
50
100
120
MIL-HDBK-217F@25℃, Ground Benign
2,000,000
---
---
CSA 60950-1 recognition,IEC/EN 60950-1(CB-scheme)
Unit
VDC
MΩ
pF
KHz
Hours
Input Fuse
5V Input Models
500mA Slow-Blow Type
12V Input Models
200mA Slow-Blow Type
24V Input Models
100mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Ambient Temperature Range (See Power Derating Curve)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Conditions
Natural Convection
Min.
Max.
-40
+85
---
+95
-50
+125
---
95
Free-Air convection
---
260
Unit
℃
℃
℃
% rel. H
℃
Power Derating Curve
Output Voltage Tolerance
+20%
+15%
+10%
+5%
Vnom
-5%
Max.
Typ.
Min.
-10%
0%
20%
40%
60%
80%
Output Load Current (%)
+20%
+15%
+10%
+5%
Vnom
-5%
-10%
100%
Notes
1 Specifications typical at Ta=+25℃, resistive load, nominal input voltage and rated output current unless otherwise noted.
2 Ripple & Noise measurement bandwidth is 0-20MHz.
3 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
modules; however they may not meet all specifications listed.
4 All DC/DC converters should be externally fused at the front end for protection.
5 Other input and output voltage may be available, please contact factory.
6 That “natural convection” is about 20LFM but is not equal to still air (0 LFM).
7 Specifications are subject to change without notice.
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com