English
Language : 

TPVI-19 Datasheet, PDF (1/2 Pages) Total Power International – UNIVERSAL INPUT AC-DC OPEN FRAME SINGLE
Total Power International, Inc.
UNIVERSAL INPUT AC-DC OPEN FRAME SINGLE &
MULTI-OUTPUT 19-20 WATTS INTERNAL SWITCHING
POWER SUPPLIES TPVI19 SERIES
FEATURES:
 ACCOMMODATE UNIVERSAL AC SOURCES
 COMPACT OPEN FRAME FORMAT
 MEET UNIVERSAL SAFETY STANDARDS
 EMI MEET CISPR PUB. 22 & FCC CLASS B
 CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Range typ. 90-264Vac.
Rating 100 to 240Vac.
Input Connector: Molex 5273(vertical).
Mating Connector: Molex 5195 or equivalent.
Input Frequency: 47-63Hz.
Inrush Current: Typ. 20A @ 230Vac.
Input Current: Typ. 0.70A @115Vac, 0.3A@230Vac.
Dielectric Withstand: Meet IEC 60950-1.
EMI: Meet CISPR PUB. 22 & FCC Class B.
Hold-up Time: Typ. 40mS @115Vac, 150mS @230Vac.
Earth Leakage: Less than 0.3mA @230Vac.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Connecter: Molex 5273 or 41671.
Mating Connector: Molex 5195 or 3069.
Output Wattage: PCB 19 watts, L-Bracket 25 watts.
Line Regulation: Typ. 0.1%.
Load Regulation: Main VO1 typ. ±1-2%
Aux. VO2 typ. ± 3-5% (stacked on).
Aux. VO3 typ. ±2-3% (P.R.).
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Built-in at Main VO1.
Adjustability: Available at Main VO1.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 70%.
Operating Temperature: 0 to +50 °C.
Switching Frequency: 40K Hz.
Storage Temperature: -20 to +85 °C.
Circuit Topology: Free-running flyback circuit.
Temperature Coefficient: Typ. 0.04% / °C.
Transient Response: Output voltage returns in less than Cooling: Free air convection cooling.
3ms following a 25% load change. Safety Standard: UL 60950-1/EN 60950-1 Class I.
Power Density: 1.26-1.58 Watts /Cubic Inch.
Construction: PCB or L-Bracket format.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
For the details of safety approval, please consult the factory.
Total Power International, Inc Toll Free: 877-646-0900(US) PH# 978-453-7272 www.total-power.com