English
Language : 

TPSPU65 Datasheet, PDF (1/2 Pages) Total Power International – 80W Desk Top Switching Power Supplies For I.T.E.
TOTAL POWER INT'L TPSPU65 SERIES
80W Desk Top Switching Power Supplies For I.T.E.
Description:
The TPSPU65 series of AC/DC switching mode power
supplies provide 80 Watts of continuous output power.
All supplies are UL 94V-0 compliant, include IEC-320-C14
input for worldwide applications. All models meet FCC Part-
15 class B and CISPR-22 class B emission Limits and are
designed to comply with UL, C-UL, TUV and CE
requirements. All units are 100% burned in and tested.
Features:
+ Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
+ IEC-320-C14 Input Inlet
+ Single to Quad Output
+ Output Voltage Available From 3 VDC Thru 48 VDC
+ Optional Output Connector (See appendix)
+ Input Surge Current, Over Voltage and Over Load protection
+ Splash proof
Safety Approvals :
+ One Year Warranty
Electrical Characteristics:
Product Safety
CB
PS
E
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin
Fin
Wo
Vo
Io
Iil
Iih
Irl
Irh
Eff
REG-i
REG-o
OVP
OCP
Ttr
Thold
Ts
Vrn
Ilk
Tc
Input Voltage
Input Frequency
Output Power Range
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Line Regulation
Load Regulation
Over Voltage Protection
Over Current Protection
Transient Response
Hold-Up Time
Start Up Time
Ripple & Noise (Pe ak to Peak)
Safety Ground Leakage Current
Temperature Coefficient
90
264
47
63
Vin=90 to 264VAC
0
80
See rating chart
See rating chart
Io=Full load, Vin=115VAC
1.9
Io=Full load, Vin=230 VAC
1.5
Io=Full load, 25°c, Cool start,
Vin=115VAC
12 15
Io=Full load, 25°c, Cool start,
Vin=230VAC
26 30
Io=Full Load, Vin=230VAC
75 83 88
Io=Full Load
0.5 1
Vin=230VAC
37
112
132
110
150
Io=Full Load to Half Load, Vin=100VAC
4
Io=Full Load, Vin=100VAC
16
Io=Full Load, Vin=100VAC
0.3 1 2
Full Load, Vin=90VAC
12
Io=Full Load, Vin=240VAC
0.5 0.75
All output
-0.04
0.04
VAC
Hz
W
V
A
A
A
A
A
%
%
%
%
%
mS
mS
S
%
mA
%/°c
Environmental :
Sym.
Parameter
Test Conditions
Toper
Tstg
Hr
Pd
Operating Temperature
Storage Temperature
Relative Humidity
Derate linearly from 100% load at 40°c to 50% load at 70°c
Safety Specifications:
Min. Typ. Max.
0
70
-40
85
5
95
Unit
°c
°c
%
Sym.
Parameter
Dielectric Withstanding Voltage
Vps
for Primary to secondary
Dielectric Withstanding Voltage
Vpg
for Primary to ground
Ri Isolation Resistance
CISPR EMI requirements for CISPR-22
FCC EMI requirements for FCC PART-15
Test Conditions
Primary to secondary
Primary to ground
Test Voltage = 500VDC
Vin=220VAC
Vin=110VAC
Min. Typ. Max. Unit
4242
VDC
2121
50
B
B
VDC
MW
CLASS
CLASS