English
Language : 

TPSPU26 Datasheet, PDF (1/2 Pages) Total Power International – 25W Interchangeable Wall Mount Type
Total Power International, Inc.
TPSPU26 SERIES
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
Interchangeable Plug
Optional Output Connector (See page appendix)
Single Output
Class II
Energy Star 2.0, Efficiency level V
2 year warranty
25W Interchangeable Wall Mount Type
I.T.E. Power Supplies
Electrical Characteristics:
Safety Approvals Input Voltage Range
Vin
Operate Voltage Range
fin Input Frequency
Po Output Power Range
Vo Output Voltage Range
Io Output Current Range
Iil Input Current (Low Line)
Iih Input Current (High Line)
Low Line Inrush Current
Ir
High Line Inrush Current
Eff Efficiency
REG-i Line Regulation
REG-o Load Regulation
OVP Over Voltage Protection
OCP Over Current Protection
Ttr Time of Transient Response
Th Hold-Up Time
Ts Start Up Time
Vp-p Ripple & Noise(Peak to Peak)
Ilk Leakage Current
TC Temperature Coefficient
Pno No-Load Power Consumption
Vps
Dielectric Withstanding Voltage
for Primary to secondary
Ris Isolation Resistance
100~240VAC
90~264VAC
47~63Hz
See rating chart
See rating chart
See rating chart
Io=Full load, Vin=100VAC
0.7A
Io=Full load, Vin=240VAC
0.4A
Io=Full load, 25°C, Cool start, Vin=115VAC
25~50A
Io=Full load, 25°C, Cool start, Vin=230VAC
50~100A
Io=Full Load, Vin=230VAC
77~85%
Io=Full Load
0.5~1%
Vin=230VAC
3~5%
Nil
Nil.But,Output protected to short circuit conditions
Io=Full Load to Half Load, Vin=100VAC
4mS (max.)
Io=Full Load, Vin=110VAC
12mS (min.)
Io=Full Load, Vin=100VAC
3S (max.)
Full Load, Vin=90VAC
2% (max.)
Vin=240VAC/60Hz
0.25mA (max.)
All output
No load, Vin=230VAC
±0.04%/°C
See rating chart
Primary to secondary
4242VDC (min.)
Test Voltage=500VDC
50M (min.)
Application:
- POS System
- AV Equipment
- Industrial PC
- Note PC
- Charger
- LED Lighting
Safety Approvals:
RoHS
2002/95/EC
COMPLIANT
UL/c-UL(UL 60950-1:2nd Edition)
TUV/GS(EN 60950-1:2nd Edition)
Environmental
To Operating Temperature
Ts Storage Temperature
Ho Operating Humidity
Hr Storage Humidity
MTBF
Operating Temperature at 25°C Calculated per MIL-HDBK-217F
,
Pd Derate linearly from 100% load at 40°C to 50% load at 70°C
See derating curve
-40~85°C
0~95%
0~95%
0.1M Hrs (min.)
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com