English
Language : 

TPSPU20B Datasheet, PDF (1/2 Pages) Total Power International – 20W Desk Top Switching Power Suplies For I.T.E.
TPSPU20B SERIES
20W Desk Top Switching Power Supplies For I.T.E.
Description:
The 20B series of AC/DC switching mode power
supplies provide 20 Watts of continuous output power and is
well-suited for a variety of applications. All supplies are UL
94V-1 min compliant. All models meet FCC Part-15 class B and
CISPR-22 class B emission Limits and are designed to comply
with UL/c-UL(UL 60950-1), TUV/GS (EN 60950-1) and new CE
requirements. All units are 100% burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C8 Input Inlet
Optional Output Connector (See appendix)
Single Output
Splash proof
Class II
CEC and Energy Star compliance
Approved as Limited Power Source (LPS).
3 year warranty
Safety Approvals:
CB
PS
E
Electrical Characteristics:
Sym.
Parameter
Test Conditions
Vin Input Voltage
Operating Voltage
fin Input Frequency
Po Output Power Range
Vin=90 to 264VAC
Vo Output Voltage Range
Io Output Current Range
Iil Input Current (Low Line)
Io=Full load, Vin=115VAC
Iih Input Current (High Line)
Io=Full load, Vin=230VAC
Irl Low Line Inrush Current
Irh High Line Inrush Current
Eff Efficiency
Io=Full load, 25c, Cool start,
Vin=115VAC
Io=Full load, 25c, Cool start,
Vin=230VAC
Io=Full Load, Vin=230VAC
REG-i Line Regulation
Io=Full Load
REG-o Load Regulation
Vin=230VAC
OVP Over Voltage Protection
OCP Over Current Protection
Ttr Time of Transient Response
Thold Hold-Up Time
Io=Full Load to Half Load,
Vin=100VAC
Io=Full Load, Vin=110VAC
Ts Start Up Time
Io=Full Load, Vin=100VAC
Vrn Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
TC Temperature Coefficient
All output
Pno No-Load Power Consumption
No load, Vin=240VAC
Min. Typ. Max. Unit
90
264 VAC
47
63 Hz
0
20
W
See rating chart V
See rating chart A
0.4 A
0.25 A
12 15
A
26 30
A
75 85 95
%
0.5 1
%
135
%
Nil
%
110
150 %
4
mS
12 14 16
0.25 0.5
0.5 1
0.15 0.25
-0.04
0.04
0 0.4 0.5
mS
S
%
mA
%/c
W
Environmental :
Sym.
Parameter
T e s t Conditions
Toper Operating Temperature
Tstg Storage Temperature
Hr Relative Humidity
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max. Unit
0
70
C
-40
85
C
5
95 %
0.3
M Hrs
Total Power International, Inc. Toll Free: 877-646-0900(US) www.total-power.com