English
Language : 

TPSPU16D Datasheet, PDF (1/2 Pages) Total Power International – 15W Desk Top Type I.T.E. Power Supplies
Total Power International, Inc.
TPSPU16D SERIES
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
A Stand And Mains AC Power Cord
Optional Output Connector (See page appendix)
Single Output
Class II
Energy Star 2.0, Efficiency level V
2 year warranty
15W Desk Top Type
I.T.E. Power Supplies
Electrical Characteristics:
Safety Approvals Input Voltage Range
Vin
Operate Voltage Range
fin Input Frequency
Po Output Power Range
Vo Output Voltage Range
Io Output Current Range
Iil Input Current (Low Line)
Iih Input Current (High Line)
Low Line Inrush Current
Ir High Line Inrush Current
Eff Efficiency
REG-i Line Regulation
REG-o Load Regulation
OVP Over Voltage Protection
OCP Over Current Protection
Ttr Time of Transient Response
Th Hold-Up Time
Ts Start Up Time
Vp-p Ripple & Noise(Peak to Peak)
Ilk Leakage Current
TC Temperature Coefficient
Pno No-Load Power Consumption
Vps
Dielectric Withstanding Voltage
for Primary to secondary
Ris Isolation Resistance
100~240VAC
90~264VAC
47~63Hz
See rating chart
See rating chart
See rating chart
Io=Full load, Vin=100VAC
0.4A
Io=Full load, Vin=240VAC
0.26A
Io=Full load, 25°C, Cool start, Vin=115VAC
15A (max.)
Io=Full load, 25°C, Cool start, Vin=230VAC
30A (max.)
Io=Full Load, Vin=230VAC
72~85%
Io=Full Load
0.5~1%
Vin=230VAC
3~7%
Nil
Nil.But,Output protected to short circuit conditions
Io=Full Load to Half Load, Vin=100VAC
4mS (max.)
Io=Full Load, Vin=110VAC
8mS (min.)
Io=Full Load, Vin=100VAC
2S (max.)
Full Load, Vin=90VAC
1% (max.)
Vin=240VAC/60Hz
0.25mA (max.)
All output
No load, Vin=230VAC
±0.04%/°C
See rating chart
Primary to secondary
4242VDC (min.)
Test Voltage=500VDC
50M (min.)
Note: The Ripple & Noise which is under 3.3VCD at 2% max
Application:
- Ethernet Hub
- Portable Devices
- Charger
- Monitor
- Set-top Box
- AV Equipment
Safety Approvals:
S&E
PS
E
RoHS
2002/95/EC
COMPLIANT
UL/c-UL(UL 60950-1:2nd Edition)
TUV/GS(EN 60950-1:2nd Edition)
Environmental
To Operating Temperature
Ts Storage Temperature
Ho Operating Humidity
Hr Storage Humidity
MTBF Operating Temperature at 25°C,Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 40°C to 50% load at 70°C
See derating curve
-40~85°C
0~95%
0~95%
0.1M Hrs (min.)
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com