English
Language : 

TPSPU131 Datasheet, PDF (1/2 Pages) Total Power International – 130W Desk Top Seitching Power Supplies For I.T.E.
TPSPU131 Series
130W Desk Top Switching Power Supplies For I.T.E.
Description:
The 131 series of AC/DC switching mode power supplies
provide 130 Watts of continuous output power . All supplies are
UL94V-1 min compliant, include IEC-320-C14 input for worldwide
applications. They are suited for use in hospital instrument and
many other applications. All models meet FCC Part-15 class B and
CISPR-22 EN55011 class B emission Limits and are designed to
comply with UL/c-UL(UL 60950-1) ,TUV/T-mark (EN 60950-1) and
new CE requirements. All units are 100% burned in and tested.
Features:
Wide Input Voltage 90 to 260 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single Output
Optional Output Connector (See appendix)
Input Surge Current, Over Voltage And Over Load protection
Output Voltage Protection
Power Factor Correction
Class I
ON/OFF SWITCH (Optional)
2 year warranty
Safety Approvals :
EN 60601-1
IEC 60601-1
Electrical Characteristics:
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin
fin
PF
Po
Vo
Io
Iil
Iih
Input Voltage
Input Frequency
Power Factor Correction
Output Power Range
Output Voltage Range
Output Current Range
Input Current (Low Line)
Input Current ( High Line)
I rl Low Line Inrush Current
I rh High Line Inrush Current
Eff Efficiency
Operating Voltage
Io=Full load, Vin=230 VAC
Vin=90 to 260 VAC
Io=Full load, Vin=115 VAC
Io=Full load, Vin=230 VAC
Io=Full load, 25 C ,Cool start,
Vin= 115VAC
Io=Full load, 25 C ,Cool start,
Vin= 230VAC
Io=Full Load, Vin=230VAC
90
260 VAC
47
63 Hz
0.95
1
0
130 W
See rating chart V
See rating chart A
1.32 A
0.66 A
30
A
50 A
88
%
REG-i
REG -o
OVP
OCP
Ttr
Thold
Ts
Vrn
Ilk
TC
Line Regulation
Io=Full Load
0.5 1
Load Regulation
Vin=230VAC
5
Over Voltage Protection
112
132
Over Current Protection
110
150
Time of Transient Response Io=Full Load to Half Load, Vin=100VAC
4
Hold-Up Time
Io=Full Load, Vin=110VAC
16
Start Up Time
Io=Full Load, Vi n= 10 0V AC
2
Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
1
Safety Ground Leakage C urrent Io = Fu ll Load, V i n = 240 V A C/60Hz
0.75
Temperature Coefficient
All output
-0.04
0.04
%
%
%
%
mS
mS
S
%
mA
%/ C
Environmental :
Sym.
Parameter
Test Conditions
Toper Operating Temperature
Tstg Storage Temperature
Hr Relative Humidity
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max. Unit
0 40 70
C
-40
85
C
5
95 %
0.1
M Hrs
Total Power International, Inc. Toll Free 877-646-0900(US) www.total-power.com