English
Language : 

TPSEU-61 Datasheet, PDF (1/2 Pages) Total Power International – 63W Enclosed Switching Power Supplies For I.T.E.
TPSEU60 SERIES
63W Enclosed Switching Power Supplies For I.T.E.
Description:
The TPSEU60 series of compact, open frame constructed, AC/DC
switching mode power supplies provide 63 Watts of continuous
output power .They are suited for use in based systems, portable
equipments and many other applications. All models meet FCC
Part-15 class B and CISPR-22 class B emission Limits and are
designed to comply with UL/c-UL(UL 60950-1), Intertek-GS(EN
60950-1) and new CE requirements. All units are 100% burned in
and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
Internal EMI filter
Single to Quad Output
Input connector mates with Molex housing 09-50-3051
and Molex 2478 series crimp terminal
Output connector mates with Molex housing 09-50-3061
(or 09-50-3081) and Molex 2478 series crimp terminal
Output Voltage Available From 3 VDC Thru 50 VDC
Input Surge Current, Over Voltage and Over Load protection
Over Voltage Protection (Crowbar Design)
Class I
2 year warranty
Electrical Characteristics:
Safety Approvals :
S&E
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin
fin
Po
Vo
Io
Iil
Iih
Irl
Irh
Eff
REG-i
REG-o
OVP
OCP
Ttr
Thold
Ts
* Vrn
Ilk
TC
Input Voltage
Operating Voltage
90
264
Input Frequency
47
63
Output Power Range
Vin=90 to 264VAC
0
63
Output Voltage Range
See rating chart
Output Current Range
See rating chart
Input Current (Low Line)
Io=Full load, Vin=115VAC
1.6
Input Current (High Line)
Io=Full load, Vin=230VAC
1.0
Low Line Inrush Current
Io=Full load, 25c, Cool start,
Vin=115VAC
12 15
High Line Inrush Current
Io=Full load, 25c, Cool start,
Vin=230VAC
26 30
Efficiency
Io=Full Load, Vin=230VAC
70 80 88
Line Regulation
Io=Full Load
0.5 1
Load Regulation
Vin=230VAC
37
Over Voltage Protection
112
132
Over Current Protection
110
150
Time of Transient Response Io=Full Load to Half Load, Vin=100VAC
4
Hold-Up Time
Io=Full Load, Vin=110VAC
12
Start Up Time
Io=Full Load, Vin=100VAC
0.3 1 2
Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
0.5 1
Safety Ground Leakage Current Io=Full Load, Vin=240VAC
0.4 0.75
Temperature Coefficient
All output
-0.04
0.04
VAC
Hz
W
V
A
A
A
A
A
%
%
%
%
%
mS
mS
S
%
mA
%/c
* Note: The Ripple & Noise which is under 3.3VCD at 2% max
_E_n_v_i_ro__n_m_e__n_t_a_l _:___________________________________________________________
Sym.
Parameter
T e s t Conditions
Min. Typ. Max. Unit
Toper Operating Temperature
0
70
C
Tstg Storage Temperature
-40
85
C
Hr Relative Humidity
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
5
0.1M
95 %
Hrs
Pd Derate linearly from 100% load at 25 C to 50% load at 70 C
_S_a_f_e_ty__S_p__e_c_if_i_c_a_t_io_n__s_: ______________________________________________________
_S_y_m__.
Parameter
T e s t Conditions
Min. Typ. Max. Unit
Vps
Dielectric Withstanding Voltage
for Primary to secondary
Primary to secondary
4242
VDC
Vpg
Dielectric Withstanding Voltage
for Primary to Ground
Primary to ground
2121
VDC
Ris Isolation Resistance
Test Voltage=500VDC
50
M
CISPR EMI requirements for CISPR-22
Vin=220VAC
B
CLASS
FCC EMI requirements for FCC PART-15
Vin=110VAC
B
CLASS