English
Language : 

TPMBU80 Datasheet, PDF (1/2 Pages) Total Power International – 80W Open Frame Type Medical Power Supplies
Total Power International, Inc.
TPMBU80 SERIES
80W Open Frame Type
Medical Power Supplies
Features:
Wide Operating Voltage 90 to 260 VAC,47 to 63 Hz
Internal EMI filter
Single Output
Active Power Factor Correction
Over Voltage and Over Load protection
Output Voltage Protection (Crowbar Design)
Size: 3"x5"x1.1"
Class I
3 year warranty
Electrical Characteristics:
Safety Approvals Input Voltage Range
Vin
Operate Voltage Range
fin Input Frequency
PF Power Factor Correction
Po Output Power Range
Vo Output Voltage Range
Io Output Current Range
Iil Input Current (Low Line)
Iih Input Current (High Line)
Low Line Inrush Current
Ir
High Line Inrush Current
Eff Efficiency
REG-i Line Regulation
REG-o Load Regulation
OVP Over Voltage Protection
OCP Over Current Protection
Ttr Time of Transient Response
Th Hold-Up Time
Ts Start Up Time
Vp-p Ripple & Noise(Peak to Peak)
Ilk Safety Ground Leakage Current
TC Temperature Coefficient
OA Operating Altitude
Pno No-Load Power Consumption
Vps Dielectric Withstanding Voltage
Vpg
Dielectric Withstanding Voltage
for Primary to PE
Ris Isolation Resistance
Io=Full load, Vin=240 VAC
Io=Full load, Vin=100VAC
Io=Full load, Vin=240VAC
Io=Full load, 25°C, Cool start, Vin=115VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Io=Full Load, Vin=230VAC
Io=Full Load
Vin=230VAC
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
Vin=240VAC/60Hz
All output
No load, Vin=230VAC
Primary to secondary
Primary to PE
Test Voltage=500VDC
Recommend to be used on the metal chassis.
Environmental
To Operating Temperature
Ts Storage Temperature
Ho Operating Humidity
Hr Storage Humidity
MTBF Operating Temperature at 25°C, Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 50°C to 50% load at 70°C
100~240VAC
90~260VAC
47~63Hz
0.95~1
See rating chart
See rating chart
See rating chart
1.2A
0.4A
28A (max.)
56A (max.)
72.5~85%
1% (max.)
5% (max.)
112~132%
110~150%
4mS (max.)
16mS (min.)
0.3~2S
1% (max.)
0.1mA (max.)
±0.04%/°C
Up to 3000m
See rating chart
6420VDC (min.)
2503VDC (min.)
50M (min.)
Application:
- Medical Touch Panel PC
- Patient Monitoring System
- Ultrasound System
Safety Approvals:
EN 60601-1
IEC 60601-1
RoHS
2002/95/EC
COMPLIANT
See derating curve
-40~85°C
0~95%
0~95%
0.1M Hrs (min.)
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com