English
Language : 

TPLSU60 Datasheet, PDF (1/2 Pages) Total Power International – 60W LED Power Supply
Total Power International, Inc.
TPLSU60 SERIES
60W LED Power Supply
Features:
Wide Operating Voltage 90 to 264 VAC,47 to 63 Hz
Internal EMI filter
Active Power Factor Correction
C.C. Mode + C.V. Mode
Constant Current: 0.84~5.45A
Constant Voltage: 11~58V
Over Voltage, Over Current, Over Over Temperature (optional)
Class I
3 year warranty
Electrical Characteristics:
Safety Approvals Input Voltage Range
Vin
Operate Voltage Range
fin Input Frequency
PF Power Factor Correction
Po Output Power Range
Vo Output Voltage Range
Io Output Current Range
Iil Input Current (Low Line)
Iih Input Current (High Line)
Low Line Inrush Current
Ir
High Line Inrush Current
Eff Efficiency
REG-i Line Regulation
Load Regulation
REG-o
Load Regulation
OVP Over Voltage Protection
Over Current Protection
OCP
Over Current Protection
Ttr Time of Transient Response
Th Hold-Up Time (C.V.)
Ts Start Up Time
Vp-p Ripple & Noise (Peak to Peak)
Ilk Safety Ground Leakage Current
TC Temperature Coefficient
Pno No-Load Power Consumption
Vps Dielectric Withstanding Voltage
Vpg
Dielectric Withstanding Voltage
for Primary to PE
Ris Isolation Resistance
Io=Full load, Vin=90~264VAC
Io=Full load, Vin=100VAC
Io=Full load, Vin=240VAC
Io=Full load, 25°C, Cool start, Vin=115VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Io=Full Load, Vin=230VAC
Io=Full Load
Vin=230VAC (C.C.)
Vin=230VAC (C.V.)
C.C.
C.V.
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
Vin=240VAC/60Hz
All output
No load, Vin=230VAC
Primary to secondary
Primary to PE
Test Voltage=500VDC
100~277VAC
90~264VAC
47~63Hz
0.90~1.0
See rating chart
See rating chart
See rating chart
1.0A
0.4A
35A (max.)
70A (max.)
84~90%
0.5~1%
3%
3%
103~105%
103~105%
140~180%
4mS (max.)
8mS (min.)
1S (max.)
1% (max.)
0.75mA (max.)
±0.04%/°C
See rating chart
4242VDC (min.)
2121VDC (min.)
50M (min.)
Application:
- Outdoor installations
Safety Approvals:
CB
BAUART
GEPRUFT
TYPE
APPROVED
IP67 RoHS
2002/95/EC
COMPLIANT
UL/c-UL(UL8750:1st edition)
TUV(EN/IEC61347-1:2008,
EN/IEC61347-2-13:2006)
CE-EMC(EN55015:2006 &
EN61547:1995+A1:2000)
Environmental
To Operating Temperature
Ts Storage Temperature
Ho Operating Humidity
Hr Storage Humidity
MTBF
Operating Temperature at 25°C Calculated per MIL-HDBK-217F
,
Pd Derate linearly from 100% load at 50°C to 50% load at 70°C
See derating curve
-40~85°C
0~95%
0~95%
0.1M Hrs (min.)
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com