English
Language : 

TPIUU-180 Datasheet, PDF (1/2 Pages) Total Power International – Wide Operating Voltage 90 to 260 VAC,47 to 63 Hz
Total Power International, Inc.
TPIUU180 SERIES
180W U Bracket Type
Industrial Power Supplies
Features:
Wide Operating Voltage 90 to 260 VAC,47 to 63 Hz
Internal EMI filter
Single Output
Active Power Factor Correction
Over Voltage Protection (Crowbar Design)
Input Surge Current and Over Load protection
Operating temperature -20~70°C
Class I
3 year warranty
Electrical Characteristics:
Safety Approvals Input Voltage Range
Vin
Operate Voltage Range
fin Input Frequency
PF Power Factor Correction
Po Output Power Range
Vo Output Voltage Range
Io Output Current Range
Iil Input Current (Low Line)
Iih Input Current (High Line)
Low Line Inrush Current
Ir
High Line Inrush Current
Eff Efficiency
REG-i Line Regulation
REG-o Load Regulation
OVP Over Voltage Protection
OCP Over Current Protection
Ttr Time of Transient Response
Th Hold-Up Time
Ts Start Up Time
Vp-p Ripple & Noise(Peak to Peak)
Ilk Safety Ground Leakage Current
TC Temperature Coefficient
Pno No-Load Power Consumption
Vps
Dielectric Withstanding Voltage
for Primary to secondary
Vpg
Dielectric Withstanding Voltage
for Primary to PE
Ris Isolation Resistance
Io=Full load, Vin=240VAC
Io=Full load, Vin=100VAC
Io=Full load, Vin=240VAC
Io=Full load, 25°C, Cool start, Vin=115VAC
Io=Full load, 25°C, Cool start, Vin=230VAC
Io=Full Load, Vin=230VAC
Io=Full Load
Vin=230VAC
Over Voltage Protection
Over Current Protection
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
Io=Full Load, Vin=100VAC
Full Load, Vin=90VAC
Vin=240VAC/60Hz
All output
No load, Vin=230VAC
Primary to secondary
Primary to PE
Test Voltage=500VDC
100~240VAC
90~260VAC
47~63Hz
0.95~1
See rating chart
See rating chart
See rating chart
2.3A
2.3A
38A (max.)
75A (max.)
85~90%
0.5~1%
2~5%
112~132%
110~150%
4mS (max.)
16mS (min.)
2S (max.)
1% (max.)
0.75mA (max.)
±0.04%/°C
See rating chart
4242VDC (min.)
2594VDC (min.)
50M (min.)
Application:
- Industrial PC
- Electrical Test & Measurement
Instruments
- Communication equipment
- AV equipment
Safety Approvals:
CB
BAUART
GEPRUFT
TYPE
APPROVED
RoHS
2002/95/EC
COMPLIANT
UL/c-UL(UL 60950-1:2nd Edition)
TUV/GS(EN 60950-1:2nd Edition)
Environmental
To Operating Temperature
Ts Storage Temperature
Ho Operating Humidity
Hr Storage Humidity
MTBF Operating Temperature at 25°C,Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 50°C to 50% load at 70°C
See derating curve
-40~85°C
0~95%
0~95%
0.1M Hrs (min.)
Total Power International, Inc
Toll Free: 877-646-0900
www.total-power.com