English
Language : 

TPIPU80 Datasheet, PDF (1/2 Pages) Total Power International – 80W desk top switching power supplies for industrial equipment
TPIPU80 SERIES
80W Desk Top Switching Power Supplies For Industrial Equipment
Description:
The 80 series of AC/DC switching mode power supplies
provide 80 Watts of continuous output power. All supplies are
UL 94V-1 min compliant, include IEC-320-C14 input for
worldwide applications. All models meet FCC Part-15 class B
and CISPR-22 class B emission Limits and are designed to
comply with UL/c-UL(UL 60950-1), TUV/GS(EN 60950-1) and
new CE requirements. All units are 100% burned in and tested.
Features:
Wide Input Voltage 90 to 260 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single Output
Optional Output Connector (See appendix)
Input Surge Current, Over Voltage And Over Load protection
Power Factor Correction
Output Voltage Protection(Crowbar Design)
Splash proof
Class I
Operating temperature -20~70 C
2 year warranty
Electrical Characteristics:
Safety Approvals :
CB
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
Operating Voltage
90
260 VAC
fin Input Frequency
47
63 Hz
PF Power Factor Correction
Io=Full load, Vin=90~260VAC
0.95 0.97 1.0
Po Output Power Range
Vin=90 to 260 VAC
0
80
W
Vo Output Voltage Range
See rating Chart V
Io Output Current Range
See rating Chart A
Iil Input Current (Low Line) Io=Full load, Vin=115VAC
1.07 A
Iih
I rl
I rh
Eff
Input Current (High Line)
Low Line Inrush Current
High Line Inrush Current
Efficiency
Io=Full load, Vin=230VAC
Io=Full load, 25 C,Cool start,
Vin=115VAC
Io=Full load, 25 C,Cool start,
Vin=230VAC
Io=Full load, Vin=230VAC
0.5 A
42 45 A
88 92 A
87
%
REG-i Line Regulation
Io=Full load
0.5 1
%
REG -o Load Regulation
Vin=230VAC
3
7
%
OVP Over Voltage Protection
112
132 %
OCP Over Current Protection
110
150 %
Ttr Time of Transient Response Io=Full load to Half Load, Vin=100VAC
4
mS
Thold Hold-Up Time
Io=Full load, Vin=110VAC
16
mS
Ts Start Up Time
Io=Full load, Vin=100VAC
0.3 1 2
S
Vp-p Ripple & Noise (Peak to Peak) Full load, Vin=90VAC
0.5 1
%
Ilk Safety Ground Leakage Current Io=Full load, Vin=240VAC
0.5 0.75 mA
TC Temperature Coefficient All output
-0.04
0.04 %/ C
Environmental :
Sym.
Parameter
T e s t Conditions
Toper Operating Temperature
Tstg Storage Temperature
Hr Relative Humidity
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max. Unit
-20
-40
5
0.1M
70
C
85
C
95 %
Hrs