TPIPU68 SERIES
60W (80Wpk) Desk Top Switching Power Supplies For Industrial Equipment
Description:
The 68series of AC/DC switching mode power supplies
provide 80W Peak output power and is well-suited for a
variety of applications. With the delay buffer duration of over
current protection, the large number of current can be acquired and
also the LPS safety requirement can be met, which is very useful for
motor driver / device ( peak load). All supplies are UL 94V-1 min
compliant. All models meet FCC-Part-15 class B and CISPR-
22 class B emission limits and are designed to comply with
UL/c-UL(UL 60950-1), TUV/GS(EN 60950-1) and new CE
requirements. All units are 100% burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C14 Input Inlet
Single output
Optional Output Connector (See appendix)
Over Voltage Protection (Crowbar Design)
Power Consumption (No load) < 0.5
Class I
CEC and Energy Star compliance
Operating temperature -20~70 C
2 year warranty
Safety Approvals :
CB
Electrical Characteristics:
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
fin Input Frequency
Po Output Power Range
Vo Output Voltage Range
Io Output Current Range
Iil Input Current (Low Line)
Iih Input Current (High Line)
Operating Voltage
Vin=90 to 264VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
90
264 VAC
47
63 Hz
0
60
W
See rating chart V
See rating chart A
1
A
0.5 A
Irl Low Line Inrush Current
Irh High Line Inrush Current
Eff Efficiency
Io=Full load, 25c, Cool start,
Vin=115VAC
12 15
A
Io=Full load, 25c, Cool start,
Vin=230VAC
26 30
A
Io=Full Load, Vin=230VAC
84
%
REG-i Line Regulation
REG-o Load Regulation
Io=Full Load
Vin=230VAC
0.5 1
%
35
%
OVP Over Voltage Protection
OCP Over Current Protection
112
132 %
110
150 %
Ttr Time of Transient Response
Thold Hold-Up Time
Io=Full Load to Half Load, Vin=100VAC
Io=Full Load, Vin=110VAC
16
4
mS
mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
Vrn Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
TC Temperature Coefficient
All output
Pno No-Load Power Consumption
No load, Vin=240VAC
0.3
0.5
0.5
-0.04
0.3
0.5
1
0.75
0.04
0.5
S
%
mA
%/c
W
Environmental :
Sym.
Parameter
T e s t Conditions
Toper Operating Temperature
Tstg Storage Temperature
Hr Relative Humidity
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 50 C to 50% load at 70 C
Min. Typ. Max. Unit
-20
-40
5
0.13M
70
C
85
C
95
%
Hrs
Total Power International, Inc.
Toll Free: 877-646-0900