English
Language : 

TPIPU20A Datasheet, PDF (1/2 Pages) Total Power International – 20W desk top switching power supplies for industrial equipment
TPIPU20A SERIES
20W Desk Top Switching Power Supplies For Industrial Equipment
Description:
The 20A series of AC/DC switching mode power
supplies provide 20 Watts of continuous output power and
is well-suited for a variety of applications. All supplies
are UL 94V-1 min compliant. All models meet FCC Part-15
class B and CISPR-22 class B emission Limits and are
designed to comply with UL/c-UL(UL 60950-1), TUV/GS
(EN 60950-1) and new CE requirements. All units are
100% burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
IEC-320-C6 Input Inlet
Optional Output Connector (See appendix)
Single Output
Splash proof
Class I
CEC and Energy Star compliance
Approved as Limited Power Source (LPS).
Operating temperature -20~70 C
3 year warranty
Electrical Characteristics:
Safety Approvals:
CB
PS
E
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
fin Input Frequency
Po Output Power Range
Vo Output Voltage Range
Io Output Current Range
Iil Input Current (Low Line)
Iih Input Current (High Line)
Operating Voltage
Vin=90 to 264VAC
Io=Full load, Vin=115VAC
Io=Full load, Vin=230VAC
90
264 VAC
47
63 Hz
0
20
W
See rating chart V
See rating chart A
0.4 A
0.25 A
Irl Low Line Inrush Current
Io=Full load, 25c, Cool start,
Vin=115VAC
12 15
A
Irh High Line Inrush Current
Eff Efficiency
Io=Full load, 25c, Cool start,
Vin=230VAC
26 30
A
Io=Full Load, Vin=230VAC
75 85 95
%
REG-i Line Regulation
Io=Full Load
0.5 1
%
REG-o Load Regulation
Vin=230VAC
135
%
OVP Over Voltage Protection
Nil
%
OCP Over Current Protection
110
150 %
Ttr Time of Transient Response Io=Full Load to Half Load, Vin=100VAC
4
mS
Thold Hold-Up Time
Io=Full Load, Vin=110VAC
12 14 16 mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
0.25 0.5 S
Vrn Ripple & Noise (Peak to Peak) Full Load, Vin=90VAC
0.5 1
%
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
0.5 0.75 mA
TC Temperature Coefficient
Pno No-Load Power Consumption
All output
No load, Vin=240VAC
-0.04
0.04 %/c
0 0.4 0.5 W
Environmental :
Sym.
Parameter
T e s t Conditions
Toper Operating Temperature
Tstg Storage Temperature
Hr Relative Humidity
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd
Derate linearly from 100% load at 40 C to 50% load at 70 C
Min. Typ. Max. Unit
-20
70
C
-40
85
C
5
95 %
0.3M
Hrs