English
Language : 

TPIPU10 Datasheet, PDF (1/2 Pages) Total Power International – 10W wall mount switching power supplies for industrial equipment
TPIPU10 SERIES
10W Wall Mount Switching Power Supplies For Industrial Equipment.
Description:
The 10 series of AC/DC switching mode power supplies
provide 10 Watts of continuous output power. All supplies are
UL 94V-0 min compliant, include a 2 prong plug-in mains
connector for certain applications. All models meet FCC class
B and are designed to comply with UL/c-UL requirements. All
units are 100% burned in and tested.
Features:
Wide Input Voltage 90 to 264 VAC,47 to 63 Hz
2 Prong Plug-In Mains Connector
Output Voltage Available From 5VDC Thru 40VDC
Optional Output Connector (See appendix)
Single Output
Energy Star 2.0, Efficiency level V
Class II
Operating temperature -20~70 C
3 year warranty
Safety Approvals:
Electrical Characteristics:
PS Agree to apply for the PSE
E if order on hand
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
Vin Input Voltage
Operating Voltage
90
264 VAC
fin Input Frequency
47
63 Hz
Po Output Power Range
Vin=90 to 264VAC
0
10 W
Vo Output Voltage Range
See rating chart V
Io Output Current Range
See rating chart A
Iil Input Current (Low Line) Io=Full load, Vin=115VAC
0.3 A
Iih Input Current (High Line) Io=Full load, Vin=230VAC
0.2 A
Irl Low Line Inrush Current
Io=Full load, 25c, Cool start,
Vin=115VAC
20 30 A
Irh High Line Inrush Current
Io=Full load, 25c, Cool start,
Vin=230VAC
45 60 A
Eff Efficiency
Io=Full Load, Vin=230VAC
75 80 85 %
REG-i Line Regulation
Io=Full Load
0.5 1
%
REG-o Load Regulation
Vin=230VAC
35
%
OVP Over Voltage Protection
Nil
%
OCP Over Current Protection Nil But,Output protected to short circuit conditions %
Ttr Time of Transient Response Io=Full Load to Half Load, Vin=100VAC
4 mS
Thold Hold-Up Time
Io=Full Load, Vin=100VAC
5 10
mS
Ts Start Up Time
Io=Full Load, Vin=100VAC
0.3 1 2
S
Vrn Ripple & Noise(Peak to Peak) Full Load, Vin=90VAC
0.5 1
%
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
0.2 0.25 mA
TC Temperature Coefficient
All output
-0.04
0.04 %/c
Environmental :
Sym.
Parameter
T e s t Conditions
Toper Operating Temperature
Tstg Storage Temperature
Hr Relative Humidity
No-Condensing
MTBF Operating Temperature at 25 C, Calculated per MIL-HDBK-217F
Pd Derate linearly from 100% load at 40 C to 50% load at 70 C
Total Power International, Inc.
Toll Free: 877-646-0900
Min. Typ. Max. Unit
-20
70
C
-40
85
C
5
95 %
0.1M
Hrs
www.total-power.com