English
Language : 

TPHPU15 Datasheet, PDF (1/2 Pages) Total Power International – 15W Interchangeable Power Supplies for MEDICAL
Total Power International, Inc.
TPHPU15 SERIES
15W Interchangeable Power Supplies for MEDICAL
Features:
Wide Operating Voltage, 80 to 275 VAC, 47 to 440 Hz
Interchangeable Plug
Single Output
Over Voltage and Over Load protection
Medical Safety 3rd (IEC60601-1 3rd Edition)
Input to Output : 2MOPP
Energy Star 2.0, Efficiency level V
Class II system
2 year warranty
Electrical Characteristics:
Vins Safety Approvals Input Voltage Range
Vin Operate Voltage Range
Fi Input Frequency
Po Output Power Range
Iil Input Current (Low Line)
Iih Input Current (High Line)
Low Line Inrush Current
Ir
High Line Inrush Current
Eff Efficiency
REG-i Line Regulation
REG-o Load Regulation
OVP Over Voltage Protection
OCP Over Current Protection
Ttr Time of Transient Response
Thu Hold-Up Time
Ts Start Up Time
Vp-p Ripple & Noise(Peak to Peak)
Tc Temperature Coefficient
Pno No-Load Power Consumption
Vps Dielectric Withstanding Voltage
EMI EMC Emission
Safety Approval & Specification in Label
100~240VAC
See derating curve
80~275VAC
Sine wave
47~440Hz
See rating chart
15W
Io=Full load, Vin=100VAC
0.6A
Io=Full load, Vin=240VAC
0.4A
Io=Full load, 25°C, Cool start, Vin=100VAC
35A (max.)
Io=Full load, 25°C, Cool start, Vin=240VAC
85A (max.)
Io=Full Load, Vin=230VAC
68~85%
Io=Full Load, Vin=100~240VAC
1% (max.)
Vin=230VAC
3~5%
Nil
Nil.But,Output protected to short circuit conditions
Io=Full Load, Vin=110VAC
4mS (max.)
Io=Full Load, Vin=110VAC
12mS (typ.)
Io=Full Load, Vin=100~240VAC
2S (max.)
Full Load, Vin=90VAC
1% (max.)
All Condition
No load, Vin=230VAC
±0.04%/°C
See rating chart
Primary to secondary
6483VDC (min.)
Compliance to EN55011 (CISPR11),
EN61000-3-2,-3
B Class
Application:
- Home Healthcare Equipment
- Patient Monitor
- Blood Pressure system
- Portable medical devices
- ECG machine
Safety Approvals:
CB
IP22
RoHS2
S&E
2011/65/EU
Environmental
To
Ts
Ho
Hr
Vsg
ESDa
ESDc
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Surge Voltage
Electro Static Discharge
Electro Static Discharge
MTBF Mean Time Between Failure
ELEV Operating Altitude (Elevation)
VBR Vibration
See derating curve
10 ~ 95% RH
Non-condensing
See Rating Chart
All Condition
Air Discharge, IEC61000-4-2
Contact Discharge, IEC61000-4-2
Operating Temperature at 25°C,
Calculated per MIL-HDBK-217F
All condition
10 ~ 500Hz, 10min./1cycle, 60min.
Each along X, Y, Z axes
-10~70°C
-40~85°C
0~95% RH
0~95% RH
2kV (min.)
8kV (min.)
6kV (min.)
0.1M Hrs (min.)
5000m (max.)
5G (min.)
Total Power International, Inc. Toll Free: 877-646-0900(U.S.) PH# (978) 453-7272
www.total-power.com
sales@total-power.com