English
Language : 

TPES18 Datasheet, PDF (1/2 Pages) Total Power International – DIVERSE AC PLUGS AVAILABLE
TOTAL POWER INT'L
UNIVERSAL INPUT AC TO DC EXTERNAL WALLMOUNT &
DESKTOP ADAPTOR SINGLE OUTPUT 16-18 WATTS
SWITCHING POWER SUPPLIES TPES18 SERIES
FEATURES:
UNIVERSAL INPUT
DIVERSE AC PLUGS AVAILABLE
WALLMOUNT OR DESKTOP FORMAT
MEET UNIVERSAL SAFETY STANDARD
EMI MEET EN55022 / FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: 90-264Vac typical.
Input Connector:
Wallmount format:WM1,2(USA/Japan)/WM3(Euro-Stecker)/
WM4(Schuko-stecker)/ WM5(UK)/
WM6, 6G(Australia)
Desktop format: IEC320 Inlet Type: DT7-3P or DT8-2P.
Mouse Power Pig-tail type: PT1/2/3/4/5/6/7.
Input Frequency: 47-63Hz.
Inrush Current: Typical 48A @230Vac or
28A @230Vac by adding thermister.
Input Current: 0.4A @115Vac/ 0.17A @230Vac.
Dielectric Withstand: Meet IEC950.
EMI: Meet EN55022 / FCC Class B.
Hold-up Time: 10mS @115Vac/ 40mS @230Vac.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 16 ~ 18 Watts typical.
Output Connector: Optional.
Line Regulation: 0.1% typical.
Load Regulation: ±1.5 ~3.0% typical.
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Built-in Zener diode clamping.
Adjustability: Factory set.
Overload Protection: Typ.120-150% of max. power
overrange or short circuit, power foldback
& self-recovering.
GENERAL SPECIFICATION
Efficiency: 75 ~ 80% typical.
Operating Temperature: 0 to +40°C.
Switching Frequency: Fixed 40KHz.
Storage Temperature: -20 to +85°C.
Circuit Topology: Fixed Frequency Flyback circuit.
Temperature Coefficient: 0.04% /°C.
Transient Response: Output voltage returns in
less than 3mS following a 25% load change.
Cooling: Free air convection.
Safety Standard: UL1950/ EN60950 Class II.
Construction: Impact resistant thermo-plastic
Class I for WM2,4,5,6G / DT7/PT 2,4,5,7.
enclosure case.
Power Density: 2.0 ~ 2.3Watts / Cubic Inch.
Wallmount or Desktop Format.
Notes: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load is varied from half load to full load (±%).
(3) The exact obtainable load regulation depends upon the output cord selected and load current. Upper data are for 6 ft.(2 meters)cord AWG#18 wires.
For the details of safety, please consult the factory
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-1-