English
Language : 

TPES14-10 Datasheet, PDF (1/2 Pages) Total Power International – AC/DC EXTERNAL DESKTOP ADAPTER UNIVERSAL INPUT MULTIPLE OUTPUT 14-16 WATTS SWITCHING POWER SUPPLIES TPES14 SERIES
TOTAL POWER INT'L
AC/DC EXTERNAL DESKTOP ADAPTER UNIVERSAL INPUT
MULTIPLE OUTPUT 14-16 WATTS SWITCHING
POWER SUPPLIES TPES14 SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC SOURCES
DESKTOP WITH IEC320 AC RECEPTACLE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET EN55022/ FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: 90-264Vac typical.
Input Connector: IEC320-3P DT7 or IEC320-2P
DT8 for dual output.
Input Frequency: 47-63Hz.
Inrush Current: 26A @230Vac typical.
Input Current: 0.4A @115Vac/ 0.2A @230Vac typical.
Dielectric Withstand: Meet IEC950.
EMI: Meet EN55022 / FCC Class B.
Hold-up Time: 10mS @115Vac or
40mS @230Vac typical.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 14-16 Watts typical.
Output Connector & Cord: Optional.
Line Regulation: 0.1% typical.
Load Regulation: Main O/P VO1 ±1.5-3.0% typical.
Aux. O/P VO2 ±3.0-5.0% typical.
Aux. O/P VO3 ±1.0-2.0% typical with P.R.
Noise & Ripple: 1.0% peak to peak typical.
OVP: Built-in “Latch type” on main output VO1 only.
Latch type or Zener diode clamp for dual output series.
Adjustability: Factory set.
Overload Protection:
125-150% typical of max. power overrange or
short circuit, power foldback & self-recovering.
GENERAL SPECIFICATION
Efficiency: 74-78% typical.
Operating Temperature: 0 °C to room temperature.
Switching Frequency: Approximate 35K Hz.
Storage Temperature: -20°C to +85°C.
Circuit Topology: Fixed Frequency Flyback circuit.
Temperature Coefficient: 0.04%/°C typical.
Transient Response: Output voltage returns in less than Cooling: Free air convection.
3mS following a 25% load change. Construction: Impact resistant thermo-plastic
Safety Standard: UL1950/ EN60950 Class I.
enclosure case.
Class II for dual output series.
Desktop Format.
Power Density: 1.12Watts / Cubic inch.
Weight : 330.0g (11.6 Oz.)
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load is varied from half load to full load (unit ±%).
For the multi-output, the main output remains 50% load and other aux. output remains 20% load.
(3) The exact obtainable load regulation depends upon the output load current & cord selected. Upper data are for 6 ft. (2 m) cord AWG#18 wires.