English
Language : 

TPAM50S_17 Datasheet, PDF (1/2 Pages) Total Power International – ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR POWER SUPPLIES 50 WATTS SINGLE
Total Power International, Inc.
ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR
POWER SUPPLIES 50 WATTS SINGLE & MULTIPLE OUTPUT
TPAM50-S, TPAM50-D & TPAM50-T SERIES
FEATURES:
ON-BOARD AC/DC MODULAR
POWER SUPPLIES
UNIVERSAL INPUT RANGE
COMPACT IN SIZE
MEET UNIVERSAL SAFETY STANDARD
EMI MEET CISPR PUB.22/ FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: 90-264Vac.
Input Frequency: 47-63Hz, 50/60Hz.Nom.
Input Current: 0.4-0.6A@115Vac typical.
0.22-0.3A@230Vac typical.
Inrush Current: 7.6-8.0A (rms) typical or
40-45A(Peak-Peak) @230Vac typical.
Input Fuse: Use internal fuse.
Dielectric Withstand: Meet IEC950.
3,000Vac-Output/Input.
EMI: Meet CISPR PUB.22/ FCC Class B.
Hold-up time: 37-54mS @115Vac typical.
180-260mS @230Vac typical.
Earth Leakage: Less than 0.25mA @230Vac.
Remote ON/OFF:
ON(Enable)=Open.
OFF(Disable)=Short.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 50 Watts typical.
Output Indicator: LED.
Line Regulation: Various with output voltage.
TPAM50S: ±0.1% typical.
TPAM50D/T: ±0.1%-0.5% typical.
Load Regulation: Various with output voltage.
VO1 ±1.0-2.0% typical.
VO2 ±3-5% typical. (Stacked On).
VO3 ±2%-3% typical. (P.R).
Noise & ripple: 1.0% typical peak to peak.
OVP: Built-in on main output.
Adjustability: Available at main output VO1.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 120-150% of rating output wattage.
Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: 72-85% typical .( Various with output voltage)
Operating Temperature: -10°C to +75°C range.
Switching Frequency: 65KHz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response Typical peak deviation 250mV,
Recovery time < 3mS for a 25% load change.
Case: Impact resistant thermo-plastic enclosure.
Power Density: 5.0 Watts. / Cubic inch.
–10°C to +50°C @ full load without derating.
From+50°C, derating linearly to half load @+75°C.
(Refer to the Derating Chart).
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: ± 0.02% /°C.
Cooling: Convection cooling for +50°C @ full load.
At least 100LFM moving air is recommended
Safety Standard: EN60950/ UL1950 Class II.
for full load >+50°C in a confined area.
MTBF: 110,000 hours. Mil Std 217, 25°C.
Commercial Grade only.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.
In application
Due to requests in market and advances in technology, specifications subject to change without notice.
Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978) 453-7272 www.total-power.com