English
Language : 

TPAM10S_17 Datasheet, PDF (1/2 Pages) Total Power International – ON-BOARD AC/DC MODULAR POWER SUPPLIES
Total Power International, Inc.
ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR
POWER SUPPLIES 10 WATTS SINGLE & DUAL OUTPUT
TPAM10S & TPAM10D SERIES
FEATURES:
 ON-BOARD AC/DC MODULAR
POWER SUPPLIES
 UNIVERSAL AC INPUT RANGE
 COMPACT IN SIZE
 MEET UNIVERSAL SAFETY STANDARDS
 EMI MEET CISPR PUB.22 / FCC CLASS B
 CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Typical 90-264Vac. (or 110-340Vdc).
Input Frequency: 47-63 Hz. (50/60Hz.Nom.) or DC.
Input Current: 0.3A at 115Vac./ 0.13A at 230Vac.
Inrush Current: 32.5A peak at 230Vac.
Input Fuse: Use external fuse. 1.0A/250Vac for
primary fuse is suggested.
Dielectric Withstand: Meet IEC950.
3,000Vac-Output/Input.
1,500Vac-Input/GND.
500Vac-Output/GND.
EMI: Meet CISPR PUB.22/ FCC Class B.
Hold-up time: 20mS at 115Vac, 80mS at 230Vac.
Earth Leakage Current: Less than 3.5mA at 230Vac.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typical 10 Watts.
Output Indicator: LED.
Line Regulation: Various with output voltage.
TPAM10S typical ±0.1%.
TPAM10D typical ±0.2%.
Load Regulation: Various with output voltage.
TPAM10S typical ±1.0%.
TPAM10D typical ±2.0%.
Noise & Ripple: Typical 1.0% peak to peak.
OVP: Built-in on main output.
Adjustability: From -10% of main output till OVP.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: Typical 67-79%. (Various with output voltage)
Switching Frequency: 75K Hz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Typical peak deviation 250mV,
Recovery time < 3mS for a 25% load change.
Case: Impact resistant thermo-plastic enclosure.
Weight: 120g (4.23 Oz).
Operating Temperature: -10 to +70°C range.
-10°C to +50°C full load without derating.
From +50°C, derating linearly to half load at +70°C.
(Refer to Derating Chart.)
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: ± 0.02% /°C.
Humidity: Up to 95%RH, Non-condensing.
Cooling: Convection cooling for +50°C at full load.
Power Density: 2.51 Watts. / Cubic inch.
At least 100LFM moving air is recommended
Safety Standard: EN60950/ UL1950 Class I.
MTBF: 100,000 hours. Mil Std 217, 25°C.
for full load > +50°C in a confined area.
Commercial Grade only.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.
(3) Due to requests in market and advances in technology, specifications subject to change without notice.
For the details of safety approval, please consult the factory.
Total Power International, Inc. Toll Free: 877-646-0900(US) PH# 978-453-7272 www.total-power.com