TPAC-175 Datasheet, PDF (1/2 Pages) Total Power International – UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC HOT-SWAP
Total Power International, Inc.
UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC HOT-SWAP
CompactPCI QUAD OUTPUT 175 WATTS CURRENT SHARING
SWITCHING POWER SUPPLIES TPAC175P & TPAC175D SERIES
FEATURES:
 175W IN 3U X 8HP EUROCARD PACKAGE
 UNIVERSAL AC INPUT WITH PFC
 INTERNAL OR-ING DIODES FOR
N+1 REDUNDANCY
 HOT-SWAPPABLE
 DROOP CURRENT SHARING
 EMI MEET EN 55022 / FCC CLASS A
 CE MARKING COMPLIANCE
 FULLY COMPLIANT WITH PICMG
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac with PFC.
Power Factor Correction: Meet Harmonic Correction
IEC 61000-3-2. Power Factor typ. 0.98.
Input Connector: PCIH47M400A1 for TPAC175P.
DIN41612 M24/8 for TPAC175D.
Input Frequency: 47-63Hz.
Inrush Current: < 30A at 230Vac by adding thermistor.
Input Current:
2.2A at 115Vac/1.1A at 230Vac for TPAC175D.
2.4A at 115Vac/1.2A at 230Vac for TPAC175P.
Dielectric Withstand: Meet IEC 60950-1 regulation.
EMI: Meet EN 55022 / FCC Class A.
Hold-up Time: 5mS at 115V & 230Vac after power fail signal.
Remote ON/OFF: Available at [INH#] & [EN#] pins.
Power Fail Signal: Available at [FAL#] pin.
Status LED: <Green> means valid input voltage.
<Amber> means a critical fault.
Thermal Protection: Installed NTC for thermal sensor
at [DEG#] pin.
Earth Leakage Current: Less than 0.5mA at 230Vac.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 175W continuous.
Output Connector: PCIH47M400A1 for TPAC175P.
DIN41612 M24/8 for TPAC175D.
Line Regulation: Typ. 0.5%.
Load Regulation: VO1 & VO2 typ. ±1.0%.
VO3 & VO4 typ. ±2.0%.
Noise & Ripple: Typ. 1% peak-peak or 50mV,
whichever is greater.
OVP: Built-in at VO1 & VO2.
Adjustability: Available at VO1 & VO2. VO3 factory set.
Remote Sensing: Available at VO1 & VO2.
Hot-Swap: Available.
N+1 Redundancy: Installed with OR-ing diodes for
N+1 redundancy operation.
Current Sharing: Droop current sharing at all output.
Power OK Signal: Available for VO1 & VO2.
Over Current Protection (OCP): Installed in all outputs.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
Consult factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: Typical 75%.
Operating Temperature: 0 to +50°C at full load with
Switching Frequency: 100 KHz.
specified air flow.
Circuit Topology: Half-bridge circuit.
Derates linearly to 50% at +70°C.
Transient Response: Typ. 1.0mS for a 25% load change.
Storage Temperature: -40°C to +85°C.
Safety Standard: IEC 60950-1/UL 60950-1 Class I.
Temperature Coefficient: Typ. ±0.02% /°C.
Construction: Eurocard 3U x 8HP x 160mm
Cooling: At least 20CFM(600LFM) airflow is required to
CompactPCI format. Front Panel with either
deliver full rating load.
Ordinary handle or Extractor handle.
Power Density: 3.2 Watts /Cubic Inch.
NOTE: (1) All measurement are at nominal input, full load and +25°C unless otherwise specifications.
(2) Due to requests in market and advances in technology, specifications subject to change without notification..
For the details of safety approval, please consult the factory.
Total Power International, Inc. Toll Free: 877-646-0900(US) PH# 978-453-7272 www.total-power.com