English
Language : 

T-40 Datasheet, PDF (1/2 Pages) Total Power International – 40W Triple Output Switching Power Supply
TOTAL POWER INT'L
40W Triple Output Switching Power Supply
T-40 series
Features :
Universal AC input / Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at 40KHz
2 years warranty
SPECIFICATION
MODEL
T-40A
T-40B
T-40C
OUTPUT
INPUT
DC VOLTAGE
5V
12V
-5V
5V
12V
-12V
RATED CURRENT
3A
2A
0.5A
3A
2A
0.5A
CURRENT RANGE
0.6 ~ 5A 0.2 ~ 3A 0.1 ~ 1A 0.6 ~ 5A 0.2 ~ 3A 0.1 ~ 1A
RATED POWER
41.5W
45W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 100mVp-p 100mVp-p 120mVp-p 120mVp-p
VOLTAGE ADJ. RANGE
CH1 : 4.75 ~ 5.5V
CH1 : 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
6.0%
8.0%
2.0%
6.0%
8.0%
LINE REGULATION
0.5%
1.0%
1.0%
0.5%
1.0%
1.0%
LOAD REGULATION
0.5%
4.0%
6.0%
0.5%
4.0%
6.0%
SETUP, RISE, HOLD TIME 800ms, 50ms, 60ms/230VAC 1.6s, 50ms,16ms/115VAC at full load
VOLTAGE RANGE
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
72%/115VAC
72%/115VAC
AC CURRENT
1.2A/115VAC 0.7A/230VAC
INRUSH CURRENT(max.) COLD START 20A/115VAC 40A/230VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
5V
15V
3A
1.5A
0.6 ~ 5A 0.2 ~ 2A
45W
100mVp-p 120mVp-p
CH1 : 4.75 ~ 5.5V
2.0%
6.0%
0.5%
1.0%
0.5%
4.0%
72%/115VAC
-15V
0.5A
0.1 ~ 1A
120mVp-p
6.0%
1.0%
4.0%
OVER LOAD
PROTECTION
OVER VOLTAGE
105 ~ 150%/115VAC of rate load
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5V: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
VIBRATION
0.03%/ (0 ~ 50 )on +5V output
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY STANDARDS
CSA 950, (UL1950, IEC950, TUV EN60950) Approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY & ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMC
(Note 4)
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A
MTBF
305.6K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
129*98*38mm (L*W*H)
PACKING
0.45Kg; 30pcs/13.5Kg/0.86CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.