1500W Single Output Power Supply
SPV-1500 series
Features :
Universal AC input/Full range
ZVS new technology
AC input active surge current limiting
Built-in active PFC function,PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Forced air cooling by built-in DC ball bearing fan
High power density 8.3W/inch3
Output voltage can be trimmed between 20% ~ 110% rated value
Current sharing up to 4500W(2+1)
Alarm signal output
Built-in 12V/0.1A auxiliary output for remote control
Built-in remote ON-OFF control
Built-in remote sense function
3 years warranty
SPECIFICATION
MODEL
SPV-1500-12
SPV-1500-24
SPV-1500-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
12V
125A
0 ~ 125A
1500W
24V
63A
0 ~ 63A
1512W
48V
32A
0 ~ 32A
1536W
OUTPUT
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
200mVp-p
VOLTAGE ADJ. RANGE
5% typical adjustment by VR, 20% ~ 110% (typ.) adjustment by 1~6VDC external control signal
VOLTAGE TOLERANCE Note.3 1.0%
LINE REGULATION
0.5%
LOAD REGULATION
0.5%
SETUP, RISE TIME
1500ms, 100ms at full load
HOLD UP TIME (Typ.)
10ms at full load
14ms at full load
16ms at full load
VOLTAGE RANGE
Note.5 90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
127 ~ 370VDC
POWER FACTOR (Typ.)
0.95/230VAC 0.98/115VAC at full load
INPUT EFFICIENCY (Typ.)
86.5%
90%
90%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
17A/115VAC
30A/115VAC
8A/230VAC
60A/230VAC
LEAKAGE CURRENT
<2.0mA / 240VAC
OVERLOAD
105 ~135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
13.8 ~ 16.8V
30 ~ 34.8V
Protection type : Shut down o/p voltage, re-power on to recover
57.6 ~ 67.2V
OVER TEMPERATURE
105 5 (TSW2 ) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
AUXILIARY POWER(AUX) 12V@0.1A(Only for Remote ON/OFF control)
REMOTE ON/OFF CONTROL Please see the Function Manual
FUNCTION
ALARM SIGNAL OUTPUT
Please see the Function Manual
OUTPUT VOLTAGE TRIM 2.4 ~ 13.2V
4.8 ~ 28V
9.6 ~ 56V
WORKING TEMP.
-20 ~ +70 (Refer to output load derating curve)
WORKING HUMIDITY
20~90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.05%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
109K hrs min. MIL-HDBK-217F (25 )
DIMENSION
278*127*83.5mm (L*W*H)
PACKING
2.6Kg; 6pcs/16.6Kg/1.54CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US) PH# (978)453-7272 www.total-power.com