SDR-960 series
¡½ Features :
¡EAC input 180~264VAC
¡E130% peak load capability
¡EWidth only 110mm
¡EBuilt-in active PFC function compliance to EN61000-3-2
¡EHigh efficiency 94% and low power dissipation
¡EProtections: Short circuit / Overload / Over voltage / Over temperature
¡ECooling by free air convection
¡EBuilt-in constant current limiting circuit
¡ECan be installed on DIN rail TS-35/7.5 or 15
¡EUL508(industrial control equipment)approved
¡EEN61000-6-2(EN50082-2) industrial immunity level
¡ECurrent sharing up to 3840W(3+1)
¡EBuilt-in DC OK relay contact
¡E100% full load burn-in test
¡E3 years warranty
SPECIFICATION
MODEL
SDR-960-24
SDR-960-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
24V
40A
0 ~ 40A
48V
20A
0 ~ 20A
RATED POWER
960W
960W
PEAK CURRENT
52A
26A
PEAK POWER
Note.6 1248W (3sec.)
OUTPUT RIPPLE & NOISE (max.) Note.2 180mVp-p
250mVp-p
VOLTAGE ADJ. RANGE
24 ~ 28V
VOLTAGE TOLERANCE Note.3 ¡Ó1.0%
LINE REGULATION
¡Ó0.5%
LOAD REGULATION
¡Ó1.0%
SETUP, RISE TIME
1000ms, 100ms/230VAC at full load
48 ~ 55V
¡Ó1.0%
¡Ó0.5%
¡Ó1.0%
HOLD UP TIME (Typ.)
14ms / 230VAC at full load
VOLTAGE RANGE Note.7 180 ~ 264VAC 254 ~ 370VDC
FREQUENCY RANGE
POWER FACTOR (Typ.)
47 ~ 63Hz
PF¡Ù0.95/230VAC at full load
INPUT
EFFICIENCY (Typ.)
94%
94%
AC CURRENT (Typ.)
6A/230VAC
INRUSH CURRENT (Typ.) COLD START 50A
LEAKAGE CURRENT
<3.5mA / 240VAC
OVERLOAD
Normally works within 105 ~ 130% rated output power for more than 3 seconds and then shut down o/p voltage with auto-recovery
after 30 seconds if the peak load condition is removed
Constant current limiting within 130 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage, re-power
PROTECTION
OVER VOLTAGE
on to recover
29 ~ 33V
56 ~ 65V
Protection type : Shut down o/p voltage, with auto-recovery or re-power on to recover
OVER TEMPERATURE
90¢J¡Ó5¢J (TSW) detect on heatsink of power switch
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
DC OK REALY CONTACT RATINGS (max.) 60Vdc/0.3A, 24Vdc/1A, 30Vac/0.5A resistive load
FUNCTION
CURRENT SHARING
Please refer to function manual
WORKING TEMP.
Note.5 -30 ~ +70¢J (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85¢J, 10 ~ 95% RH
TEMP. COEFFICIENT
¡Ó0.03%/¢J (0 ~ 50¢J)
VIBRATION
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY STANDARDS
UL508, UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
OTHERS
NOTE
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25¢J/ 70% RH
EMC EMISSION
Compliance to EN55022 (CISPR22), EN61204-3 , EN61000-3-2,-3
EMC IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A
MTBF
69.8K hrs min. MIL-HDBK-217F (25¢J)
DIMENSION
110*125.2*150mm (W*H*D)
PACKING
2.47Kg ; 6pcs/15.8Kg/1.55CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¢J of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.
In case the adjacent device is a heat source, 15mm clearance is recommended.
6. 3 seconds peak power max. and the average output power should not exceed the rate power.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.