RSP-1000 Datasheet, PDF (1/6 Pages) Mean Well Enterprises Co., Ltd. – 1000W Single Output Power Supply
1000W Single Output Power Supply
RSP-1000 series
Features :
Universal AC input / Full range
AC input active surge current limiting
Built-in 5V/0.5A auxiliary power
Built-in active PFC function, PF>0.95
Protections: Short circuit / Overload / Over voltage / Over temperature
Output voltage can be trimmed between 40 ~ 110% of the rated output voltage
Forced air cooling by built-in DC fan
High power density 10.7w/inch3
1U low profile 41mm
Active current sharing up to 4000W(3+1) (Note.8)
DC OK Signal
Built-in remote ON-OFF control
Built-in remote sense function
SPECIFICATION
3 years warranty
..
MODEL
RSP-1000-12
RSP-1000-15
RSP-1000-24
RSP-1000-27
RSP-1000-48
DC VOLTAGE
12V
15V
24V
27V
48V
RATED CURRENT
60A
50A
40A
37A
21A
CURRENT RANGE
0 ~ 60A
0 ~ 50A
0 ~ 40A
0 ~ 37A
0 ~ 21A
RATED POWER
720W
750W
960W
999W
1008W
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
OUTPUT VOLTAGE ADJ. RANGE
10 ~ 13.5V
13.5 ~ 16.5V
20 ~ 26.4V
24 ~ 30V
43 ~ 55V
VOLTAGE TOLERANCE Note.3 1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
LOAD REGULATION
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME
300ms, 50ms at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load
VOLTAGE RANGE Note.5 90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
0.95/230VAC 0.98/115VAC at full load
INPUT EFFICIENCY (Typ.)
83%
85%
88%
88%
90%
AC CURRENT (Typ.)
12A/115VAC 6A/230VAC
INRUSH CURRENT (Typ.) 25A/115VAC 40A/230VAC
LEAKAGE CURRENT
<2.0mA / 240VAC
OVERLOAD
105 ~ 125% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
13.8 ~ 16.8V
17 ~ 20.5V
27.6 ~ 32.4V
Protection type : Shut down o/p voltage, re-power on to recover
31 ~ 36.5V
56.6 ~ 66.2V
OVER TEMPERATURE
85 5 (TSW2 ) detect on heatsink of O/P diode; 75 5 (TSW1 ) detect on heatsink of power transistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
AUXILIARY POWER(AUX) 5V @ 0.5A (+5%, -8%)
REMOTE ON/OFF CONTROL Note.6 Power on : short between on/off(pin6) & -S(pin2) on CN50 Power off : open between on/off(pin6) & -S(pin2) on CN50
FUNCTION DC OK SIGNAL
The TTL signal out, PSU turn on = 3.3 ~ 5.6V ; PSU turn off = 0 ~ 1V
OUTPUT VOLTAGE TRIM Note.6 Adjustment of output voltage is possible between 40 ~ 110% of rated output
CURRENT SHARING(CS)Note.7 Please refer to function manual
WORKING TEMP.
-20 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
0.02%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22)
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
OTHERS
NOTE
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A
MTBF
35K hrs min. MIL-HDBK-217F (25 )
DIMENSION
295*127*41mm (L*W*H)
PACKING
1.95Kg; 6pcs/12.7Kg/0.99CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
6. The power supply unit will have no output if the shorting connector is not assembled. It contains two shorting wires: one is from on/off(pin6) to -s(pin2)
and the other is from Vco(pin8) to Vca(pin10). Please refter to function manual for details.
7. In parallel connection, maybe only one unit operate if the total output load is less than 5% of rated load condition.
8. Please consult MEAN WELL for applications of more units connecting in parallel.