English
Language : 

Q-250 Datasheet, PDF (1/2 Pages) Total Power International – 250W Quad Output Power Supply
TOTAL POWER INT'L
250W Quad Output Power Supply
Q-250 series
Features :
AC input range selected by switch
Protections:Short circuit/Over load/Over voltage
Forced air cooling by built-in DC fan
100% full load burn-in test
Fixed switching frequency at 75KHz
Low cost
High reliability
2 years warranty
SPECIFICATION
MODEL
Q-250B
Q-250C
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
+5V
20A
2 ~ 20A
201W
+12V
7A
0.5 ~ 7A
-12V
1A
0.5 ~ 1A
-5V
1A
0 ~ 1A
+5V
20A
2 ~ 20A
195W
+15V
5A
0.5 ~ 5A
-15V
1A
0.5 ~ 1A
-5V
1A
0 ~ 1A
OUTPUT
INPUT
RIPPLE & NOISE (max.) Note.2 80mVp-p
120mVp-p 120mVp-p 50mVp-p
80mVp-p
VOLTAGE ADJ. RANGE
4.75 ~ 5.5V
4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0%
+8, -10%
10%
6.0%
2.0%
LINE REGULATION
0.5%
1.0%
1.0%
1.0%
0.5%
LOAD REGULATION
1.0%
6.0%
8.0%
2.0%
1.0%
SETUP, RISE, HOLD TIME 800ms, 50ms, 20ms at full load
VOLTAGE RANGE
90 ~ 132VAC / 176 ~ 264VAC Selected by switch 248 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
73%
74%
AC CURRENT
6A/115VAC 3.5A/230VAC
INRUSH CURRENT (max.) COLD START 50A
150mVp-p
10%
1.0%
8.0%
150mVp-p
10%
1.0%
10%
50mVp-p
6.0%
1.0%
2.0%
LEAKAGE CURRENT
<2mA / 240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
+5V: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
WORKING TEMP.
-10 ~ +60 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50 )
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
EMC
ISOLATION RESISTANCE
UL60950 Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
MTBF
219.5K hrs min. MIL-HDBK-217F (25 )
OTHERS DIMENSION
150*140*86mm (L*W*H)
PACKING
1.5Kg; 8pcs/12Kg/0.97CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.