English
Language : 

PBA300F Datasheet, PDF (1/1 Pages) Total Power International – PBA300F
Unit type
PBA300F
R
Ordering information
PBA 300 F
1
2
3
-5 -O
4
5
1Series name
2Output wattage
3Universal input
4Output voltage
5 Optional
C :with Coating
G :Low leakage current
U :Operation stop voltage
is set at a lower value
F3 :Reverse air exhaust
type
F4 :Low speed fan
Refer to instruction manual
7.1
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA300F-3R3
198
ACIN 100V 3.3V 60A
ACIN 200V *3 3.3V 60A
PBA300F-5
300
5V 60A
5V 60A
PBA300F-7R5
300
7.5V 40A
7.5V 40A
PBA300F-12
324
12V 27A
12V 27A
PBA300F-15
330
15V 22A
15V 22A
PBA300F-24
336
24V 14A
24V 14(16.5)A
PBA300F-36
324
36V 9A
36V 9A
PBA300F-48
336
48V 7A
48V 7A
SPECIFICATIONS
MODEL
VOLTAGE[V]
PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48
AC85 - 264 1f or DC120 - 350 (AC50 or DC70 optionally available *4)
CURRENT[A]
FREQUENCY[Hz]
ACIN 100V 3typ
ACIN 200V 1.6typ
4.1typ
2typ
50/60 (47 - 63)
INPUT
EFFICIENCY[%]
POWER FACTOR
ACIN 100V 68typ
ACIN 200V 71typ
74typ
77typ
ACIN 100V 0.98typ (Io=100%)
ACIN 200V 0.95typ (Io=100%)
76typ
79typ
78typ
81typ
78typ
81typ
79typ
82typ
81typ
84typ
INRUSH CURRENT[A] ACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
ACIN 200V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start)
LEAKAGE CURRENT[mA]
0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1)
VOLTAGE[V]
3.3
5
7.5
12
15
24
36
79typ
82typ
48
CURRENT[A]
ACIN 100V 60
ACIN 200V *3 60
LINE REGULATION[mV]
20max
LOAD REGULATION[mV]
40max
RIPPLE[mVp-p]
0 to +50C*1 80max
-20 - 0C*1 140max
60
60
20max
40max
80max
140max
40
40
36max
60max
120max
160max
27
27
48max
100max
120max
160max
22
22
60max
120max
120max
160max
14
14(16.5)
96max
150max
120max
160max
9
9
144max
150max
150max
160max
7
7
192max
300max
150max
400max
OUTPUT
RIPPLE NOISE[mVp-p]
0 to +50C*1
-20 - 0C*1
120max
160max
120max
160max
150max
180max
150max
180max
150max
180max
150max
180max
200max
240max
200max
500max
0 to +50C*1 40max
TEMPERATURE REGULATION[mV] -20 to +50C*1 60max
50max
75max
75max
120max
120max
180max
150max
180max
240max
290max
360max
440max
480max
600max
DRIFT[mV]
*2 12max
20max
30max
48max
60max
96max
144max
192max
START-UP TIME[ms]
300typ(ACIN 100/200V, Io=100%) Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage.
HOLD-UP TIME[ms]
20typ (ACIN 100/200V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96
3.96 - 6.00 5.25 - 8.25
8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00
OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40
5.00 - 5.15 7.50 - 7.80
12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92
OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically
PROTECTION OVERVOLTAGE PROTECTION[V] 4.3 - 6.3
CIRCUIT AND OPERATING INDICATION
LED (Green)
OTHERS
REMOTE SENSING
Provided
6.5 - 8.0
9.0 - 11.6
14.4 - 18.6
18.0 - 23.3
28.8 - 37.2
REMOTE ON/OFF
INPUT-OUTPUT -RC
Provided
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
INPUT-FG
ISOLATION OUTPUT-RC-AUX-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
OUTPUT-RC -AUX
AC100V 1minute, Cutoff current = 100mA, DC100V 50MWmin (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
43.2 - 54.0
57.6 - 80.0
ENVIRONMENT
STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
IMPACT
AGENCY APPROVALS
SAFETY AND CONDUCTED NOISE
NOISE
REGULATIONS CE MARKING
HARMONIC ATTENUATOR
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
-20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
19.6m/s2 (2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input)
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2
102X42X170mm (without terminal block and screw) (WXHXD) /1.0kg max
Forced cooling (internal fan)
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail.
*4 Derating is required.Consult us for details.
* A sound may occur from power supply at pulse loading.