English
Language : 

PBA-150 Datasheet, PDF (1/1 Pages) Total Power International – Output voltage setting potentiometer externally
Unit type
PBA150F
R
Ordering information
PBA 150 F
1
2
3
-5 -O
4
5
1Series name
2Output wattage
3Universal input
4Output voltage
5 Optional
C :with Coating
G :Low leakage current
(0.15mA max / ACIN 240V)
E :Low leakage current
and EMI class A
(0.5mA max / ACIN 240V)
T :Vertical terminal block
J :Connector type
(Only -12,-15,-24,-36,-48)
R :with Remote ON/OFF
N :with Cover
(Only 24V UL508 is acquired)
N1 :with DIN rail
V :Output voltage setting
potentiometer external-
ly
Specification is changed at
option. Please consult us
details.
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
PBA150F-3R3 PBA150F-5
99
150
3.3V 30A
5V 30A
PBA150F-9
150.3
9V 16.7A
PBA150F-12
156
12V 13A
PBA150F-15
150
15V 10A
PBA150F-24
156
24V 6.5A
PBA150F-36
154.8
36V 4.3A
PBA150F-48
158.4
48V 3.3A
SPECIFICATIONS
MODEL
VOLTAGE[V]
PBA150F-3R3 PBA150F-5 PBA150F-9 PBA150F-12 PBA150F-15
AC85 - 264 1f or DC120 - 370 (AC50 or DC70 optionally available *4)
INPUT
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 1.3typ
ACIN 200V 0.7typ
2.0typ
1.0typ
50/60 (47 - 63)
ACIN 100V 80typ
83typ
ACIN 200V 82typ
86typ
82typ
85typ
83typ
86typ
84typ
87typ
OUTPUT
POWER FACTOR(Io=100%)
ACIN 100V 0.98typ
ACIN 200V 0.87typ
0.99typ
0.93typ
ACIN 100V 20typ (Io=100%) (At cold start)
INRUSH CURRENT[A]
ACIN 200V 40typ (Io=100%) (At cold start)
LEAKAGE CURRENT[mA]
0.4/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1)
VOLTAGE[V]
3.3
5
9
12
15
CURRENT[A]
30
30
16.7
13
10
LINE REGULATION[mV]
20max
20max
36max
48max
60max
LOAD REGULATION[mV]
40max
RIPPLE[mVp-p]
0 to +50C*1 80max
-10 - 0C*1 140max
40max
80max
140max
100max
120max
160max
100max
120max
160max
120max
120max
160max
0 to +50C*1 120max
RIPPLE NOISE[mVp-p] -10 - 0C*1 160max
120max
160max
150max
180max
150max
180max
150max
180max
TEMPERATURE REGULATION[mV]
DRIFT[mV]
START-UP TIME[ms]
0 to +50C 50max
50max
-10 to +50C 60max
60max
*2 20max
20max
350typ(ACIN 100V, Io=100%)
90max
120max
36max
120max
150max
48max
HOLD-UP TIME[ms]
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.63
4.00 - 5.50 7.50 - 10.0
10.0 - 13.2
OUTPUT VOLTAGE SETTING[V] 3.20 - 3.40
4.90 - 5.20 8.70 - 9.30
11.5 - 12.5
OVERCURRENT PROTECTION Works over 105% of rated current and recovers automatically
150max
180max
60max
13.2 - 18.0
14.5 - 15.5
PBA150F-24
85typ
88typ
24
6.5
96max
150max
120max
160max
150max
180max
240max
290max
96max
19.2 - 27.0
23.5 - 24.5
PBA150F-36
85typ
88typ
36
4.3
144max
240max
150max
200max
250max
300max
360max
450max
144max
28.8 - 39.6
35.5 - 36.5
PBA150F-48
85typ
88typ
48
3.3
192max
240max
150max
200max
250max
300max
480max
600max
192max
39.0 - 53.0
47.0 - 49.0
PROTECTION OVERVOLTAGE PROTECTION[V] 4.00 - 5.25
5.75 - 7.00
CIRCUIT AND OPERATING INDICATION
LED (Green)
11.5 - 14.0
OTHERS
REMOTE SENSING
Optional (Only -3R3, -5 Option -K)
15.0 - 18.0
20.0 - 25.0
30.0 - 37.0
43.0 - 50.0
REMOTE ON/OFF
Optional (Required external power source)
INPUT-OUTPUT -RC
*3 AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
ISOLATION INPUT-FG
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-FG
*3 AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature)
OPERATING TEMP.,HUMID.AND ALTITUDE -10 to +71C (Required Derating), 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
ENVIRONMENT STORAGE TEMP.,HUMID.AND ALTITUDE
VIBRATION
-20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max
19.6m/s2 (2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis
IMPACT
196.1m/s2 (20G), 11ms, once each X, Y and Z axis
AGENCY APPROVALS
SAFETY AND CONDUCTED NOISE
NOISE
REGULATIONS CE MARKING
HARMONIC ATTENUATOR
UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input)
Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Low Voltage Directive, EMC Directive
Complies with IEC61000-3-2
OTHERS
CASE SIZE/WEIGHT
COOLING METHOD
34X93X168mm (without terminal block) (WXHXD) / 560g max (without cover)
Convection
*1 Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN :
RM101).
*2 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C.
*3 Applicable when Remote ON/OFF(optional) is added. RC is insulated with input, output and
FG.
*4 Derating is required.Consult us for details.
* Parallel operation with other model is not possible.
* Derating is required when operated with cover.
* A sound may occur from power supply at peak loading.
58.0 - 65.0