PB-230 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 230W Single Output Battery Charger
230W Single Output Battery Charger
PB-230 series
Authorized Distributor: Total Power International, Inc.
Toll Free: 877-646-0900 PH# 978-453-7272
www.total-power.com
Features :
3 stage charging characteristic
Universal AC input / Full range
Built-in active PFC function, PF>0.95
Protection: Short circuit / Overload / Over voltage / Over temperature
Built-in cooling Fan ON-OFF control
Built-in remote ON-OFF control
2 color LED loading indicator
Low cost, high reliability
2 years warranty
TUV
( for PB-230-xxAD1 only) Rheinland
Product Safety
geprUfre
Sicherheit
ORDER NO.
OUTPUT CONNECTOR
SAFETY
PB-230-xx (standard model)
4pin power din
TUV / CE
PB-230-xxAD1 (optional model)
Anderson connector
UL / TUV / CE
PB-230-xx xx=12,24,48 ; =Blank, AD1
SPECIFICATION
MODEL
PB-230-12
PB-230-24
PB-230-48
BOOST CHARGE VOLTAGE 14.4V
FLOAT CHARGE VOLTAGE 13.6V
28.8V
27.2V
57.6V
54.4V
RECOMMENDED BATTERY
OUTPUT
50 ~ 160Ah
CAPACITY(AMP HOURS)(Note 5)
24 ~ 80Ah
12 ~ 40Ah
BATTERY TYPE
Open & Sealed Lead Acid
OUTPUT CURRENT
16A
8A
4A
VOLTAGE RANGE
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.98/115VAC at full load
INPUT EFFICIENCY (Typ.)
82%
85.5%
86%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
3A/115VAC 1.5A/230VAC
COLD START 50A
LEAKAGE CURRENT
<3.5mA / 240VAC
OVERLOAD
90 ~ 110% rated output current
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION
FUNCTION
OVER VOLTAGE
OVER TEMPERATURE
REMOTE CONTROL (CN105)
FAN CONTROL
TEMPERATURE SENSE
16 ~ 18V
31 ~ 35V
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Automatically derate charge current until zero
Open: Normal work Short: Stop Charging
RTH3 50 Fan ON, 45 Fan OFF (Typ.)
By NTC
59 ~ 64V
WORKING TEMP.
-20 ~ +50 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY STANDARDS
UL1012(for PB-230-xxAD1 only), TUV EN60950-1 approved
SAFETY &
EMC
(Note 4)
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
MTBF
OTHERS DIMENSION
PACKING
PLUG
CONNECTOR
CABLE
244.5Khrs min. MIL-HDBK-217F (25 )
190*96*49mm(L*W*H)
1.16Kg; 12pcs/14.9Kg/1.29CUFT
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.