English
Language : 

PB-120 Datasheet, PDF (1/2 Pages) Total Power International – 120W Single Output Power Supply or Battery Charger
PA / P B - 1 2 0 120W Single Output Power Supply or Battery Charger
series
Authorized Distributor: Total Power International, Inc.
Toll Free: 877-646-0900(US) PH# (978)453-7272 www.total-power.com
Features :
AC input range selected by switch
Built-in passive PFC function compliance to EN61000-3-2
With AC ON-OFF switch
3 poles AC inlet with fuse holder
Protections: Short circuit / Overload / Over voltage / Over temperature
Charger type can be selected (Optional)
Charger for lead-acid batteries
2 color LED loading indicator
Open frame models available (Without safety approval)
Low cost, High reliability
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
S:Power Supply
P A 120 P 13 C
A:Voltage detector
B:Current detector
P:With PFC
N:None PFC
:O.D.M. number
P:Open P.C.B.
C:With case
13:13.8V
27:27.6V
54:55.2V
SPECIFICATION
MODEL
PA/PB-120 -13
PA/PB-120 -27
PA/PB-120 -54
OUTPUT
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
13.8V
7.2A
0 ~ 7.2A
99.36W
27.6V
4.3A
0 ~ 4.3A
118.68W
55.2V
2.2A
0 ~ 2.2A
121.44W
LED INDICATED
PA series voltage 105% 1% : RED / 105% 1% :GREEN
PB series load 46% 10% : GREEN / 46% 10% :RED
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
88 ~ 132VAC / 176 ~ 264VAC selected by switch
47 ~ 63Hz
>0.65 (with PFC series)
INPUT EFFICIENCY (Typ.)
73%
79%
79%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
3A/115VAC 1.5A/230VAC
COLD START 25A/115VAC 50A/230VAC
LEAKAGE CURRENT
<1.5mA / 240VAC
OVERLOAD
90 ~ 110% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
PROTECTION OVER VOLTAGE
15 ~ 17V
30 ~ 35V
60 ~ 66V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER TEMPERATURE
RTH2 70 10 detect on RTH2 thermistor
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
WORKING TEMP.
-10 ~ +45 (Refer to output load derating curve)
WORKING HUMIDITY
20 ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY -20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.05%/ (0 ~ 45
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY &
EMC
(Note 4)
SAFETY STANDARDS
UL60950-1, TUV EN60950-1, EN60335, EN60335-1, EN60335-2-29 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
HARMONIC CURRENT
Compliance to EN61000-3-2,-3
EMS IMMUNITY
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
OTHERS
MTBF
DIMENSION
PACKING
149.6K hrs min. MIL-HDBK-217F (25 )
PCB Type:144*90*33mm External case type:180*96*49mm (L*W*H)
1.1Kg; 16pcs / 17.9Kg / 1.47CUFT(without PFC) 1.24Kg; 16pcs / 20.1Kg / 1.47CUFT(with PFC)
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. With PFC I/P range: 95~132VAC/190~264VAC.
6. For open P.C.B. WITH 17.8CFM min. Forced air.