English
Language : 

NET-50 Datasheet, PDF (1/2 Pages) Mean Well Enterprises Co., Ltd. – 50W Triple Output Switching Power Supply
50W Triple Output Switching Power Supply
Authorized Distributor: Total Power International, Inc. Toll Free: 877-646-0900(US)
NET-50 series
PH# (978)453-7272 www.total-power.com
Features :
Universal AC input/Full range
Protections:Short circuit/Over load/Over voltage
Cooling by free air convection
100% full load burn-in test
2 years warranty
SPECIFICATION
MODEL
NET-50A
NET-50B
NET-50C
NET-50D
OUTPUT
OUTPUT NUMBER
CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3 CH1 CH2 CH3
DC VOLTAGE
5V
12V
-5V
5V
12V
-12V 5V
15V
-15V 5V
24V
12V
RATED CURRENT
4A
2A
0.5A 4A
2A
0.5A 4A
1.5A 0.5A 3A
1A
1A
CURRENT RANGE Note.6 0.6 ~ 5A 0.2 ~ 2.5A 0.1 ~ 0.7A 0.6 ~ 5A 0.2 ~ 2.5A 0.1 ~ 0.7A 0.6 ~ 5A 0.1 ~ 2A 0.1 ~ 0.7A 0.6 ~ 5A 0.1 ~ 1.5A 0.1 ~ 1.5A
RATED POWER
46.5W
50W
50W
51W
RIPPLE & NOISE (max.) Note.2 80mVp-p 120mVp-p 120mVp-p 80mVp-p 120mVp-p 120mVp-p 80mVp-p 150mVp-p 150mVp-p 80mVp-p 200mVp-p 120mVp-p
VOLTAGE ADJ. RANGE
CH1:4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
CH1: 4.75 ~ 5.5V
VOLTAGE TOLERANCE Note.3 2.0% 6.0% 5.0% 2.0% 6.0% 5.0% 2.0% 8.0% 5.0% 2.0% 8.0% 6.0%
LINE REGULATION Note.4 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% 0.5% 1.0% 1.0% 0.5% 1.0% 1.0%
LOAD REGULATION Note.5 1.5% 3.0% 1.0% 1.5% 3.0% 1.0% 1.5% 3.0% 1.0% 1.5% 3.0% 3.0%
SETUP, RISE TIME
500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD TIME (Typ.)
50ms/230VAC 10ms/115VAC at full load
VOLTAGE RANGE
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
INPUT
EFFICIENCY (Typ.)
76%
78%
78%
80%
AC CURRENT (Typ.)
1.1A/115VAC 0.65A/230VAC
INRUSH CURRENT (Typ.) COLD START 45A
LEAKAGE CURRENT
<2mA / 240VAC
OVER LOAD
PROTECTION
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1: 5.75 ~ 6.75V
Protection type : Shut down o/p voltage, re-power on to recover
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
-20 ~ +60 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 45 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CB(IEC60950-1) Approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
EMC
(Note 6)
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
Compliance to EN61000-4-2, 3, 4, 5, 6, 8,11, ENV50204, EN55024, EN61000-6-1 Light industry level, criteria A
OTHERS
NOTE
MTBF
348.4K hrs min. MIL-HDBK-217F (25 )
DIMENSION
129*98*38mm (L*W*H)
PACKING
0.44Kg; 45pcs/21Kg/1.24CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.