English
Language : 

HSU200 Datasheet, PDF (1/2 Pages) Total Power International – AUTO-RANGING AC INPUT AC-DC MULTIPLE OUTPUT 200 WATTS 19 COMPATIBLE DOUBLE EUROCARD SWITCHING POWER SUPPLIES HSU200 SERIES
TOTAL POWER INT'L
AUTO-RANGING AC INPUT AC-DC MULTIPLE OUTPUT
200 WATTS 19" COMPATIBLE DOUBLE EUROCARD
SWITCHING POWER SUPPLIES HSU200 SERIES
FEATURES:
„AUTO-RANGING AC INPUT
„19" COMPATIBLE EUROCARD FORMAT
„MEET THE SAFETY STANDARDS
„EMI MEET CISPR PUB.22 & FCC CLASS A
„CE MARKING COMPLIANCE
„12HP X 6U X160MM DOUBLE EUROCARD
VMEbus STANDARD
SPECIFICATION
INPUT SPECIFICATION
Input Voltage: Auto-ranging 115Vac(90-132Vac) and
230Vac(180-264Vac).
Transient threshold typ. 150Vac.
Input Connector: DIN 41612 at rear.
Input Frequency: 47-63Hz
Inrush Current: Typ. 65.0A @ 230Vac.
Input Current: Typ. 3.3A/115Vac & 1.6A/230Vac.
Dielectric Withstand: Meet IEC950.
EMI: Meet CISPR PUB.22 or FCC Class A.
Hold-up Time: Typ. 26mS.
Power OK: Installed
Remote Inhibit: Installed.
Over Temp. Protection (OTP): Installed (Thermostate).
Power-On LED: Installed.
Earth leakage: Typ. 0.3 mA @230Vac.
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 200 Watts.
Output Connector: DIN 41612 at rear.
Line Regulation: Typ. 0.2%.
Load Regulation: Main VO1 typ. ±1.0%.
Aux. VO2 typ. ±1-2.0%(MA).
Aux. VO3 typ. ±2-3.0%(PR).
Aux. VO4 typ. ±2-3.0%(PR).
Noise & Ripple: Typ. 1% peak to peak.
OVP: Available at main VO1 & Aux.VO2.(latch).
Adjustability: Available at VO1 & VO2.
Remote Sense: Installed at main VO1.
Overload Protection (OLP): Fully protected against
output overload and short circuit. Typ. 130% full load.
Consult the factory for OLP setting.
Output LED Indicators: Installed for all outputs.
GENERAL SPECIFICATION
Efficiency: Typ. 76-77.0%.
Operating Temperature: 0 to +50°C at full load.
Switching Frequency: Typ. 100K Hz.
Derate linearly to +70°C at half load.
Circuit Topology: Forward circuit.
Storage Temperature: -20 to +85°C.
Transient Response: Output voltage returns in less than
Temperature Coefficient: Typ. 0.04%/°C.
1.5mS following a 25% load change.
Cooling: Free air convection.
Safety Standard: IEC950/UL1950 Class I.
Construction format: 12HPx6U compatible double
Power Density: 1.30 Watt / Cubic Inch.
Eurocard VMEbus standard.
Note: All measurements are at nominal input, full load, and +25°C unless otherwise specified.
TOTAL POWER, INT. Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-1-